Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Fluke 117 Digital Multimeter
DC millivolts
Range/Resolution: 600.0 mV / 0.1 mV
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/Resolution:; 600.0 V / 0.1 V
Accuracy:
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolt True RMS
Range/Resolution: 600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts True RMS
Range/Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy:
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/Resolution: 600 Ω / 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
500 μs or longer.
Ohms
Range/Resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy: 0.9% + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5% + 2
Diode test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
Lo-Z capacitance
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)
Range/Resolution
6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy:
1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/Resolution: 6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy
1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)
Range/Resolution
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2
Fluke 323 True RMS Clamp Meter
AC current
Range: 400.0 A
Accuracy:
2% ±5 digits (45 Hz to 65 Hz)
2.5% ±5 digits (65 Hz to 400 Hz)
AC voltage
Range: 600.0 V
Accuracy: 1.5% ±5 digits
DC voltage
Range: 600.0 V
Accuracy: 1.0% ±5 digits
Resistance
Range/Resolution: 400.0 Ω/ 4000 Ω
Accuracy: 1.0% ±5 digits
Continuity: ≤ 70 Ω
AC response: True RMS
Data hold: Yes