Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Operating Temperature: 32° to +158°F (0° to +70°C)
Materials:
Enclosure: Expanded UV protected PVC
Bottle: Two 1 gallon Polyethylene
Pickup Hose: 15 ft reinforced PVC 1/4" ID polyethylene flexible tubing section with intake strainer
Pump Tubing: Norprene 1/4 inch ID, 7/16 inch OD
Sample Pump:
Flow Rate: 1000 ml per minute at a 4 foot head
Type: Peristaltic
Maximum Lift: ~20 feet
Power: Rechargeable 5 AH Gel Cell (Pump running continuously: 1 pump-1h, 2pumps-1/2h)
Standby: 3 months while still retaining enough power to run both pumps to capacity
Start Delay: 16 time settings from 0 to 12 hours
Composite Interval: 15 time settings from 5 min. to 12 hours plus an External Trigger mode setting
Sample Size: 15 composite sample sizes from 50 ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
External Trigger Input: 250mS minimum pulse width
Switch closure or 4-30VDC
Pulse Output: 5VDC one-second pulse
1000ohm output impedance
Bottle Switch Input: Switch closure input
Floating switch in bottle
Rain and Water Sensors: Optional moisture sensors or switch closure inputs
Internal Fuse: 10A Slow-Blow
Charger: 18 VDC Regulated Switching Supply, 330 mA 6 Watt, 2.1 mm Connector
Size of unit: 22x18x10 inch (56x45.7x25.4 cm) (HxWxD)
Weight: 30 lb (13.6 kg)