Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

|
PCS-1000 I Specifications |
|||
|
General |
|||
|
Power Supply |
100 V / 120 V / 220 V / 240 V ±10% |
||
|
Power Line Frequency |
50/60 Hz |
||
|
Operating Environment |
Full accuracy for0 ℃to55 ℃, Full accuracy to 80% R.H. at40 ℃ |
||
|
Storage Environment |
-40 ℃to70 ℃ |
||
|
Power Consumption |
Max 35VA |
||
|
Dimensions |
210 mm(W) *80 mm(H) *390mm(D) |
||
|
Weight |
Approxiately5 kg |
||
|
DC Characteristics |
|||
|
DC Voltage |
|||
|
Range |
1 Year23 ℃±5 ℃ |
Temperature |
|
|
200.0000 mV |
|
0.0050 + 0.0035 |
0.0005 + 0.0005 |
|
2.000000 V |
|
0.0050 + 0.0010 |
0.0005 + 0.0001 |
|
20.00000 V |
|
0.0050 + 0.0010 |
0.0005 + 0.0001 |
|
200.0000 V |
|
0.0050 + 0.0010 |
0.0005 + 0.0001 |
|
1000.000 V |
|
0.0050 + 0.0020 |
0.0005 + 0.0001 |
|
Accuracy specification : ± (% of reading + % of range) |
|||
|
Voltage input Resistance:10MΩ for all DC Voltage ranges |
|||
|
|
|||
|
DC Current |
|||
|
Range |
Burden Voltage |
1 Year23 ℃±5 ℃ |
Temperature |
|
30.00000 mA |
<0.4 V |
0.01 + 0.005 |
0.001 + 0.002 |
|
300.0000 mA |
<0.5 V |
0.01 + 0.005 |
0.001 + 0.002 |
|
3.000000 A |
<0.8 V |
0.01 + 0.005 |
0.001 + 0.002 |
|
30.00000 A*1 |
<0.8 V |
0.01 + 0.005 |
0.001 + 0.002 |
|
300.0000 A*1 |
<0.8 V |
0.02 + 0.005 |
0.001 + 0.002 |
|
Accuracy specification : ± (% of reading + % of range) |
|||
|
|
|||
|
Isolated DC Current Monitor Accuracy |
|||
|
Range |
Resolution( 6 1/2) |
DC Accuracy |
Temperature |
|
30.00000 mA |
0.00001mA |
0.1+0.05 |
0.001 |
|
300.0000 mA |
0.0001mA |
0.1+0.05 |
0.001 |
|
3.000000 A |
0.000001A |
0.1+0.05 |
0.001 |
|
30.00000 A*1 |
0.00001A |
0.1+0.05 |
0.001 |
|
300.0000 A*1 |
0.0001A |
0.2+0.05 |
0.001 |
|
Accuracy specification : ± (% of output + % of full scale) |
|||
|
Monitor output voltage for the full scale current = 3V |
|||
|
|
|||
|
AC Characteristics |
|||
|
|
|||
|
True RMS AC Voltage |
|||
|
Range |
Frequency |
1 Year23 ℃±5 ℃ |
Temperature |
|
200.0000 mV |
45Hz - 2kHz |
0.5 + 0.05 |
0.005 + 0.005 |
|
2.000000 V |
0.005 + 0.005 |
||
|
20.00000 V |
0.005 + 0.005 |
||
|
200.0000 V |
0.005 + 0.005 |
||
|
600.000 V |
0.005 + 0.005 |
||
|
Accuracy specification : ± (% of reading + % of range) |
|||
|
|
|||
|
True RMS AC Current |
|||
|
Range |
Frequency |
1 Year23 ℃±5 ℃ |
Temperature |
|
30.00000 mA |
45Hz - 2kHz |
0.5 + 0.05 |
0.03 + 0.006 |
|
300.0000 mA |
0.03 + 0.006 |
||
|
3.000000 A |
0.03 + 0.006 |
||
|
30.00000 A*1 |
45Hz - 400Hz |
0.5 + 0.05 |
0.03 + 0.006 |
|
300.0000 A*1 |
0.03 + 0.006 |
||
|
Accuracy specification : ± (% of reading + % of range) |
|||
|
|
|||
|
Isolated AC Current Monitor Accuracy |
|||
|
Range |
Frequency |
AC Accuracy |
Max Input Limit |
|
30.00000 mA |
45Hz - 2kHz |
0.2 + 0.05 |
30 mA |
|
300.0000 mA |
300 mA |
||
|
3.000000 A |
3 A |
||
|
30.00000 A*1 |
45Hz - 400Hz |
0.5 + 0.05 |
30 A |
|
300.0000 A*1 |
300 A |
||
|
Accuracy specification : ± (% of output + % of full scale) |
|||
|
Monitor output voltage for the full scale current = 3V |
|||
|
The specifications are only applicable when the input is 10% or greater of the full scale range |
|||
(The specifications apply when the PCS-1000I is powered on for at least 30 minutes to warm-up to a temperature of18 ℃to28 ℃, unless specified otherwise.)
*1 The accuracy for30A/300Alevels must be increased by a power factor of 8 ppm/watt.