| GDS-1072A-U | | |
| VERTICAL |
| Channels | 2 | | |
| Bandwidth | DC ~70MHz(-3dB) | | |
| Rise Time | <5ns approx="" span=""> | | |
| Sensitivity | 2mV/div ~ 10V/div (1-2-5 increments) |
| Accuracy | ±(3% x |Readout| + 0.1 div + 1mV) |
| Input Coupling | AC, DC & Ground |
| Input Impedance | 1MΩ±2%, ~15pF |
| Polarity | Normal & Invert |
| Maximum Input | 300V (DC+AC peak), CATII |
| Waveform Signal Process | + , - , x, FFT, FFTrms ,Zoom FFT |
Offset Range
| 2mV/div ~ 50mV/div: ±0.4V 100mV/div ~ 500mV/div: ±4V 1V/div ~ 5V/div: ±40V 10V/div: ±300V |
| Bandwidth Limit | 20MHz (-3dB) |
| TRIGGER |
| Sources | CH1 , CH2 , Line , EXT |
| Modes | Auto, Normal, Single, TV, Edge, Pulse Width |
| Coupling | AC , DC , LF rej. , HF rej. , Noise rej. |
| Sensitivity | DC ~ 25MHz: Approx. 0.5div or 5mV; 25MHz ~ 70/100/150MHz: Approx. 1.5div or 15mV |
| EXT TRIGGER |
| Range | ±15V |
| Sensitivity | DC ~ 25MHz : ~ 50mV ; 25M ~ 70/100/150MHz : ~15mV |
| Input Impedance | 1MΩ±2% , ~ 15pF |
| Maximum Input | 300V (DC AC peak) , CATII |
| HORIZONTAL |
| Range | 1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 50ms/div ~ 50s/div |
| Modes | Main, Window, Window Zoom, Roll, X-Y |
| Accuracy | ±0.01% |
| Pre-Trigger | 10 div maximum |
| Post-Trigger | 1000 div |
| X-Y MODE |
| X-Axis Input | Channel 1 |
| Y-Axis Input | Channel 2 |
| Phase Shift | ±3°at 100kHz |
| SIGNAL ACQUISITION |
| Real-Time Sample Rate | 1GSa/s maximum |
| Equivalent Sample Rate | 25GSa/s maximum |
| Vertical Resolution | 8 Bits |
| 2 Mega Points maximum |
| Acquisition Mode | Normal, Peak Detect, Average |
| Peak Detection | 10ns (500ns/div ~ 10s/div) |
| Average | 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 |
| CURSORS AND MEASUREMENT |
| Voltage Measurement | Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot |
| Time Measurement | Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle |
| Cursors Measurement | Voltage difference between cursors (V) Time difference between cursors (T) |
Auto Counter
| Resolution : 6 digits Accuracy: 2% Signal Source: All available trigger source except the Video trigger mode |
| ADJUSTABLE PROBE COMPENSATION SIGNAL |
| Frequency Range | 1kHz ~ 100kHz, 1kHz/STEP |
| Duty Cycle Range | 5% ~ 95%, 5%/STEP |
| CONTROL PANEL FUNCTION |
| Autoset | Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically |
| Save Setup | Up to 15 sets of measurement conditions |
| Save Waveform | 15 sets of waveform |
| DISPLAY |
| TFT LCD Type | 5.7 inch |
| Display Resolution | 234(Vertically) x 320(Horizontally) Dots |
| Display Graticule | 8 x 10 divisions |
| Display Brightness | Adjustable |
| INTERFACE |
| USB Device | USB1.1 & 2.0 full speed compatible (Pictbridge Compatibility Printers Supported) |
| USB Host | Image (BMP), waveform data (CSV), and setup (SET) |
| POWER SOURCE |
| Line Voltage Range | AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection |
| MISCELLANEOUS |
| Multi-Language Menu | Available |
| Onscreen Help | Available |
| DIMENSIONS & WEIGHT |
| 310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg |