Accessories: ; User Manual x 1; Power Cord x 1, Test Lead GTL-104x2, GTL-105x1; GTL-201x1, GTL-203x1, GTL-204x2
|
OUTPUT RATINGS
|
| CH1/CH2 Independent |
0 ~ 30V / 0 ~ 6A ; 0 ~ 60V / 0 ~ 3A |
| CH1/CH2 Series |
0 ~ 60V / 0 ~ 6A ; 0 ~ 120V / 0 ~ 3A |
| CH1/CH2 Parallel |
0 ~ 30V / 0 ~ 12A ; 0 ~ 60V / 0 ~ 6A |
| CH3 |
0.1 ~ 5V / 3A |
| VOLTAGE REGULATION |
| Line |
≦0.01% + 3mV |
| Load |
≦0.01% + 5mV (rating current ≦6A) ≦0.01% + 8mV (rating current ≦12A) |
| Ripple & Noise |
≦5mVrms (5Hz ~ 1MHz ) ≦ 50mVpp (20Hz ~ 20MHz) |
| Recovery Time |
≦100μs(50% load change, minimum load 0.5A) |
| CURRENT REGULATION |
| Line |
≦0.2% + 3mA |
| Load |
≦0.2% + 3mA |
| Ripple & Noise |
≦3mArms |
| TRACKING OPERATION |
| Tracking Error |
≦0.5% + 10mV of master |
| Series Regulation |
≦300mV |
| Ripple & Noise |
≦10mVrms (5Hz ~ 1MHz) ≦100mVpp (20Hz ~ 20MHz) |
| OUTPUT ON/OFF RESPONSE TIME |
| Voltage Up (10% ~ 90%) |
≦100ms ( ≦ 95% rating load) |
| Voltage Down (90% ~ 10%) |
≦100ms ( ≧ 10% rating load) |
| OVP |
| Accuracy |
± (0.5% of reading + 0.5V) |
| METER |
| Type |
3 1/2 digits 0.5" LED display |
| Accuracy |
± (0.5% of reading + 2 digits) |
| Resolution |
100mV/10mA |
| INSULATION |
| Chassis & Terminal |
100MΩ or above (DC 1000V) |
| Chassis & AC code |
100MΩ or above (DC 1000V) |
| TEMPERATURE COEFFICIENT |
| Voltage |
≦ 100ppm/°C + 3mV |
| Current |
≦ 150ppm/°C + 3mA |
| REMOTE CONTROL |
| |
Output On/Off |
| FAN NOISE |
| |
≦50dB |
| OPERATION ENVIRONMENT |
| |
Ambient temperature 0 ~ 40℃ Relative humidity ≦ 80% |
| STORAGE ENVIRONMENT |
| |
Ambient temperature -10 ~ 70℃ Relative humidity ≦70% |
| POWER SOURCE |
| |
AC 115V/230V ±15%, 50/60Hz |
| ACCESSORIES |
| |
User manual x 1, Power code x 1 Test lead GTL-104 x 2, GTL-105 x 1 or European test lead GTL-201 x 1, GTL-203 x 1, GTL-204 x 2 |
| DIMENSIONS & WEIGHT |
| |
255 (W) x 145 (H) x 265 (D) mm Approx. 6kg |