Mainframe
Microprocessor controlled touch screen: 5”, 800x480, 24 bit
Optical-Interface for remote control of the generator: optional
Interface for saving reports: USB
External trigger input/output: 10 V at 1 kΩ
Mains power: 230 V / 50 Hz / 10 VA
Dimensions of desk top case (W * H * D): 450 * 180 * 300 mm³
Weight: 5 kg
Direct high-voltage-input: 10 kV DC / 7 kV AC
External input (Ri = 1000 kΩ): 100 V ≡ 100 %
Calibration possibility of the preamplifier: ± 2 %
Analogue output (Ri = 5 kΩ): 5 V ≡ 100 % or 1 mA ≡ 100 %
Setting Parameter / Evaluation input voltage:
DC: Average
AC: + / - Peak / √2
Impulse: + / - Peak
Impulse: Reset
Measurement input: Intern / Extern
Time interval for storing the measurement value: 1s – 3600s
Resolution AD-converter: 12 Bit / 4096
Digital display: Autorange
Precision (AC/DC): 1.0 %
Precision (Impulse): 2.5 %
Bandwidth: 0 - 10 kHz
Environmental temperature: 17 °C - 23 °C