DC Voltage range : 0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)
Accuracy: ±2.5 % f.s. Max. rated voltage: 600 V
AC Voltage range : 12 V (9 k-ohm/V) Accuracy: ±4 % f.s.
30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s.
Average rectifier effective value Max. rated voltage: 600 V
DC Current range : 60 µA/30 m/300 mA (300 mV internal voltage drop)
Accuracy: ±3 % f.s.
Resistance range : 0 to 3 k-ohm (center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k
Accuracy: ±3 % of scale length
Battery check : 0.9 to 1.8 V, load resistance 10 ohm, Accuracy: ±6 % f.s.
Temperature scale : -20 to 150°C, Use with R ×100 range (Thermister Temperature Probe 9021-01 is necessary, sold separately), Accuracy: ±3 % of scale length
Power supply : For resistance measurement range, R6P (AA) × 2 batteries
Dimensions, mass : 95 mm(3.74 in)W × 141 mm(5.55 in)H × 39 mm(1.54 in)D, 280 g (9.9 oz)
Supplied accessories : TEST LEAD×1, Spare fuse×1, Manganese batteries (R6P)×2, Instruction Manual×1, CARRYING CASE 9390×1
| DC Voltage range | 0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V) Accuracy: ±2.5 % f.s. Max. rated voltage: 600 V |
| AC Voltage range | 12 V (9 k-ohm/V) Accuracy: ±4 % f.s. 30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s. Average rectifier effective value Max. rated voltage: 600 V |
| DC Current range | 60 µA/30 m/300 mA (300 mV internal voltage drop) Accuracy: ±3 % f.s. |
| Resistance range | 0 to 3 k-ohm (center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k Accuracy: ±3 % of scale length |
| Battery check | 0.9 to 1.8 V, load resistance 10 ohm, Accuracy: ±6 % f.s. |
| Temperature scale | -20 to 150°C, Use with R ×100 range (Thermister Temperature Probe 9021-01 is necessary, sold separately), Accuracy: ±3 % of scale length |
| Power supply | For resistance measurement range, R6P (AA) × 2 batteries |
| Dimensions, mass | 95 mm(3.74 in)W × 141 mm(5.55 in)H × 39 mm(1.54 in)D, 280 g (9.9 oz) |
| Supplied accessories | TEST LEAD×1, Spare fuse×1, Manganese batteries (R6P)×2, Instruction Manual×1, CARRYING CASE 9390×1 |