Measurement method : DC, AC+DC (True RMS), AC (True RMS/ Average rectified)
Peak value display: Absolute value (of waveform peak)
Separate AC from DC: output Separate constituent element of AC, DC
Output (terminal 1): Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)
Output (terminal 2): Rms current/Low-battery warning switch
Integral current measurement : ±, +, - integral, average value
Rate measurement: Operating time rate, total measurement time
Timer settings : 99 hr, 59 min. (for repeated up to 20 times)
Data storage: Peak, integral value, operating time rate, or other
Basic accuracy at DC current: option Clamp
+ 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
+ 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
+ 200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A
Basic accuracy at AC current(45 to 66 Hz)
+ 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
+ 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
+ 200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A
Frequency measurement: 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.
Crest factor: 2.5 or later, or rated peak value of sensor
Frequency characteristic: DC, or 1 Hz to 1 kHz (accuracy guaranteed range)
Power supply: LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)
Dimensions, mass: 155 mm W × 98 mm H × 47 D, 545 g
Supplied accessories Carrying strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1
| All the Functions You Need for Measurement at DC or 1Hz and Up |
|
| Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
| 3290 | 3290-10 | |
| Measurement method | DC, AC+DC (True RMS), AC (True RMS/ Average rectified) | DC, AC+DC (True RMS), AC (True RMS) |
| Peak value display | Absolute value (of waveform peak) | Polarities independently (±peak value of waveform, in DC mode) |
| Separate AC from DC output | Separate constituent element of AC, DC | None |
| Output (terminal 1) | Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range) | Current waveform or true RMS value (2 V / setting range) |
| Output (terminal 2) | Rms current/Low-battery warning switch | Current integral value (1 VDC / setting range) |
| Integral current measurement | None | ±, +, - integral, average value |
| Rate measurement | None | Operating time rate, total measurement time |
| Timer settings | None | 99 hr, 59 min. (for repeated up to 20 times) |
| Data storage | None | Peak, integral value, operating time rate, or other |
| Basic accuracy at DC current | 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A 200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A |
|
| Basic accuracy at AC current (45 to 66 Hz) |
20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A 20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A 200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A |
|
| Voltage measurement | None | |
| Frequency measurement | 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt. | |
| Crest factor | 2.5 or later, or rated peak value of sensor | |
| Frequency characteristic | DC, or 1 Hz to 1 kHz (accuracy guaranteed range) At monitor output: based on the using sensor |
|
| Other functions | Selectable of response time, filter (fc=550 Hz) | |
| Power supply | LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible) | |
| Dimensions, mass | 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz) | |
| Supplied accessories | Carrying strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1 | |
CLAMP ON HiTESTER SERIES
product catalog.pdf (1.96 MB) (2013-01-23 updated)