Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

SPECIFICATIONS
- Measurement parameters: Cs, Cp (capacitance), D (loss coefficient tan δ)
- Measurement range: Cs, Cp (capacitance), D (loss coefficient tan δ)
- Basic accuracy:
(typical value) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016
Measurement accuracy = Basic accuracy × B × C × D × E, B to E is coefficient
- Source frequency: 120Hz, 1kHz
- Measurement signal level:
100mV (3504-60 only), 500mV, 1V rms
Measurement range CV 100mV: up to 170μF range (Source frequency 1kHz), up to 1.45mF range (Source frequency 120Hz)
Measurement range CV 500mV: up to 170μF range (Source frequency 1kHz), up to 1.45mF range (Source frequency 120Hz)
Measurement range CV 1V: up to 70μF range (Source frequency 1kHz), up to 700μF range (Source frequency 120Hz)
- Output resistance: 5Ω
- Display: LED (six digits, full scale count depends on measurement range)
- Measurement times: 2ms typical (1 kHz, FAST mode)
- Function:
4-terminal contact check function (3504-60 only)BIN (measurement values can be classified by rank) (3504-50, 3504-60), Trigger-synchronous output, Setting configurations can be stored, Comparator, Averaging, Low-C reject (bad contact detection), Chatter detection, EXT. I/O, RS-232C (all models standard), GP-IB (3504-50, 3504-60)
- Power supply: Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 110VA max.
- Dimensions, mass: 260mm(10.24in)W × 100mm(3.94in)H × 220mm(8.66in)D, 3.8kg(134.0oz)
- Supplied accessories: Power cord(1), Fuse(1)
- The warranty period: 12 month
| Measurement parameters | Cs, Cp (capacitance), D (loss coefficient tan δ) |
| Measurement ranges | C: 0.9400 pF to 20.0000 mF, D: 0.00001 to 1.99000 |
| Basic accuracy | (typical value) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016 Measurement accuracy = Basic accuracy × B × C × D × E, B to E is coefficient |
| Source frequency | 120Hz, 1kHz |
| Measurement signal level | 100mV (3504-60 only), 500mV, 1V rms Measurement range CV 100mV: up to 170μF range (Source frequency 1kHz), up to 1.45mF range (Source frequency 120Hz) Measurement range CV 500mV: up to 170μF range (Source frequency 1kHz), up to 1.45mF range (Source frequency 120Hz) Measurement range CV 1V: up to 70μF range (Source frequency 1kHz), up to 700μF range (Source frequency 120Hz) |
| Output resistance | 5Ω (In open terminal voltage mode outside of the CV measurement range) |
| Display | LED (six digits, full scale count depends on measurement range) |
| Measurement times | 2ms typical (1 kHz, FAST mode) Actual measurement time depends on measurement configuration settings |
| Function | 4-terminal contact check function (3504-60 only) BIN (measurement values can be classified by rank) (3504-50, 3504-60), Trigger-synchronous output, Setting configurations can be stored, Comparator, Averaging, Low-C reject (bad contact detection), Chatter detection, EXT. I/O, RS-232C (all models standard), GP-IB (3504-50, 3504-60) |
| Power consumption | Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 110VA max. |
| Dimensions, mass | 260mm(10.24in)W × 100mm(3.94in)H × 220mm(8.66in)D, 3.8kg(134.0oz) |
| Supplied accessories | Power cord × 1, Spare fuse × 1 |
Catalog
3506, 3505, 3504-60, 3504-50, 3504-40
product catalog.pdf (1.1 MB) (2008-06-30 updated)