Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

- Measurement line & number of circuits: 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
- Measurement items:
+ Voltage/current RMS, voltage/current fundamental wave value, voltage / current fundamental wave phase angle, frequency, voltage waveform peak (absolute value), current waveform peak (absolute value), active/reactive/ apparent power, power factor (lag/lead) or displacement power factor (lag/ lead), active energy (consumption, regeneration), reactive energy (consumption, regeneration), active power demand quantity (consumption, regeneration), reactive power demand quantity (lag/lead), active power demand value (consumption, regeneration), reactive power demand value (lag/lead), power factor demand, energy cost
+ Pulse input
+ [PW3360-21 only]: Harmonic (level of voltage/current/power, content ratio, phase angle, total value, THD-F, THD-R), up to 40th order
- Voltage ranges: 600 V AC
- Current ranges (option clamp)
+ 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
+ 50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
- Power ranges 300.00 W to 9.0000 MW (Depends on voltage/current combination and measured line type)
-Basic accuracy
+ Voltage : ±0.3% rdg. ±0.1% f.s
+ Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
+ Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
- Display update rate: 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
- Save destination: SD Memory card, or internal memory at real time
- Data save interval: 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
- Save items: Measurement value save: Average only / average, maximum, minimum value
- Screen copy: BMP form (saved every 5 min. at minimum interval time)
- Waveform save: Binary waveform data
- Interfaces:
SD memory card,
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
- Functions:Connection check, Quick Set navigation guide, clock, pulse input
- Power supply: AC adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
- Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
- Dimensions, mass 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
- Accessories Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5