Specification
-Measurement methods: Measurement of voltage drop across body simulated resistance points
Calculation and display of current values True rms measurement
Measurement unit floats relative to instrument ground.
- Measurement modes: Leak current measurement, voltage measurement, safety conductor current measurement
- Standard compliance:
+ IEC IEC 60990 (1999)
+ IEC 61010-1 (2001)
+ UL-1492 (1996)
+ IEC 60335-1 (2001) + A1:2004 + A2:2006
+ IEC 60065 (2001) + A1:2005
+ UL-2231-1 (2002), UL-2231-2 (2002)
- Leak current measurement: Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
- Measurement current: DC, AC (15 Hz to 1 MHz), AC+DC (15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
- Measurement ranges: DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA
- Measurement accuracy: DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
- Interfaces: External I/O, medical device relay output, USB 1.1 (communications), RS-232C
- Functionality: 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
- HiTESTER power supply: 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
- Target device power supply input: 100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
- Dimensions, mass: 320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg
- Supplied accessories: TEST LEAD L2200 (for ST5540, Red ×2, Black ×1) ×1 set, ENCLOSURE PROBE 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, Users guide ×1, CD-ROM ×1
- The warranty period: 12 month
| Measurement methods | Measurement of voltage drop across body simulated resistance points Calculation and display of current values True rms measurement Measurement unit floats relative to instrument ground. |
| Measurement modes | Leak current measurement, voltage measurement, safety conductor current measurement |
| Standard compliance | Electrical Appliances and Materials Safety Act Measurement of touch current and protective conductor current: IEC 60990 (1999) Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001) Information technology equipment: IEC 60950-1 (2005) Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006 Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005 Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002) UL: UL-1492 (1996) Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001) |
| Leak current measurement | Ground leak current, 3 types of contact current, free current measurement, 3 types of enclosure leak current |
| Measurement current | DC, AC (true rms, 15 Hz to 1 MHz), AC+DC (true rms, 15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz) |
| Measurement ranges | DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA AC peak mode:500 μA/1 mA/10 mA/75 mA |
| Measurement accuracy (current measurement) |
DC measurement: ±2.0% rdg. ±6 dgt. (typ.) AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.) AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.) |
| Interfaces | External I/O, USB 1.1 (communications), RS-232C |
| Functionality | Automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc. |
| HiTESTER power supply | 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power |
| Target device power supply input | 100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A |
| Target device power supply output | Output from terminal block: 20 A Output from outlet: 15 A |
| Dimensions, mass | 320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg (158.7 oz) |
| Supplied accessories | TEST LEAD L2200 (Red ×1, Black ×1) ×1 set, ENCLOSURE PROBE 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, Users guide ×1, CD-ROM ×1 |