Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

1. Contact AE PD detection
Detection frequency band: 10kHz~300kHz
Detection sensitivity: ≤10pC
Linearity error: ≤±10%
Stability error: ≤±5%
Dynamic range: ≥60dB
Gain: 0~60dB
Signal acquisition: 16bit, 10MS/s
Measurement range: 0~80dB
2. Non-contact AE PD detection
Detection frequency band: 10kHz~300kHz
Center frequency: 40kHz
Detection sensitivity: ≤10pC
Linearity error: ≤±10%
Stability error: ≤±5%
Dynamic range: ≥60dB
Gain: 0~60dB
Signal acquisition: 16bit, 10MS/s
3. UHF PD detection
Working frequency band: 300M~1500MHz
Detection sensitivity: ≤0.1pC
Average effective height: ≥11mm
Stability error: ≤±5%
Dynamic range: ≥60dB
Signal acquisition: 16bit, 250MS/s
4. HF PD detection
Detection frequency band: 3MHz~30MHz
Detection sensitivity: ≤5pC
Transmission impedance: ≥5mV/mA
Linearity error: ≤±3%
Stability error: ≤±5%
Dynamic range: ≥60dB
Gain: 22dB~72dB;
Signal acquisition: 16bit, 250MS/s
5. Transient ground voltage PD detection
Working frequency band: 3M~100MHz
Gain: 0~60dB
Minimum discharge capacity: ≤10pC
Pulse counting error: ≤5%
Positioning accuracy: 30cm
Linearity error: ≤±3%; Stability error: ≤±5%
Dynamic range: ≥60dB
Signal acquisition: 16bit, 250MS/s
6. Main unit parameters
Lithium battery pack: 24V/5AH
Synchronization: external synchronization AC10~380V, with virtual synchronization function; wireless synchronization AC10~380V
Display interface: true color, viewing area 152×92mm, resolution 800×480
System platform: WinCE6.0, 1 network port, 1 USB port, support flash drive
Weight: 236×177×53mm, about 1.5Kg
Use environment: temperature -10 ~ 55 ºC, humidity RH90% or less.