pH Range: -2.000~20.000 pH
- Resolution: 0.1/0.01/0.001pH
- Accuracy: ±0.003pH
- pH Buffer Groups: USA, NIST, NIST2, DIN, Custom
- Calibration points: Up to 5 (USA, NIST, NIST2, Custom) / Up to 6 (DIN)
ORP Range: ± 2000.0mV
- Resolution: 0.1mV
- Accuracy: ±0.2mV
- Calibration option: Yes (Up to ± 200 mV)
Ion Range: 0.000 µg/L to 9999 g/L
- Units: µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
- Resolution: 4 Significant digits
- Accuracy: ± 0.3% full scale or ± 0.2 mV, whichever is higher
- Calibration Points: Up to 5
Conductivity Range: 0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
- Units: Auto ranging S/cm, S/m (µS ↔ mS ↔ S)
- Resolution: 0.05% full scale
- Accuracy: ± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm
- Reference temperature: 15.0 to 30.0 °C (adjustable)
- Temperature coefficient; 0.00 to 10.00 % per °C (adjustable)
- Cell constants: 0.070 to 13.00 (adjustable)
- Calibration points: Up to 4 (Auto) / Up to 5 (Manual)
Resistivity range: 0.001 MΩ・cm to 20.0 MΩ・cm
- Resolution: 0.5% full scale
- Accuracy: ± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ・cm
Total Dissolved Solids (TDS) Range: 0.01 to 9.99 mg/L (ppm)
10.0 to 99.9 mg/L (ppm)
100 to 999 mg/L (ppm)
1.00 to 9.99 g/L (ppt)
10.0 to 100 g/L (ppt)
- Resolution: 0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)
- Accuracy: ± 0.1% full scale
- TDS Curves: EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity range: 0.0 to 100.0 ppt / 0.00 to 10.00 %
- Resolution: 0.1 ppt / 0.01%
- Accuracy: ± 0.2% full scale
- Salinity curves: NaCl / Seawater
- Calibration option: Yes (Manual; 1 point)
Temperature range: -30.0 to 130.0°C / -22.0 to 266.0°F
- Resolution: 0.1 °C / °F
- Accuracy: ± 0.5 °C / ± 0.9 °F
- Calibration option: Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory: 2000
Auto Data Log: Yes
Real-time Clock: Yes
Date & Time Stamp: Yes
Measurement modes: Auto Stable / Auto Hold / Real Time
Offset & Slope Display: Yes (Segment & Average Slopes)
Calibration Alarm: Yes (Programmable: up to 90 days)
Auto shut-Off: Yes (Programmable: up to 30 mins.)
Electrode status: On screen display
Diagnostics: Yes
Password setting: Yes
Software upgrade: Yes
PC / Printer communication: Phono jack (USB / RS232C)
Meter Inputs: 2 x BNC, 2 x phono (ATC), DC sockets
Display: 5" Custom LCD with backlight and 320 segments
Power requirement: AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight: 155(L) x 150(W) x 67(H) mm, 770g