- DC Voltage: 0.0V ~ 690.0V; ±(0.5%reading + 2digits)
- AC TRMS, DC, AC+DC TRMS, LoZ Voltage: 0.5V ~ 690.0V; 32Hz ~ 1kHz; ±(0.5%reading + 2digits)
- AC TRMS Current with Flexible clamp F3000U: 1A ~ 3000A; ±(0.5%reading + 2digits)
- AC TRMS, DC, AC+DC TRMS Current with Standard clamp: 1mV ~ 1000mV; ±(0.5%reading + 2digits)
- Inrush current (DIRC) - Flexible clamp F3000U: 1A ~ 3000A; ±(2.0%reading + 2digits)
- Inrush current (DIRC) - Standard clamp: 1mV ÷ 1000mV; ±(2.0%reading + 2digits)
- Resistance and Continuity test: 0.0Ω ~ 1999Ω; ±(1.0%reading + 5digits)
- Voltage / Current Harmonics: 42.5Hz ~ 69Hz; ±(5.0%reading + 10digits)
- Phase rotation test with 1-wire method:100V ~ 690V ; 42.5Hz ~ 69Hz
- Test on RCD protection devices
+ RCD type: AC, A, General
+ L-PE voltage range: 100V ~ 690V
+ Frequency range: 42.5Hz ~ 69Hz
- Overall earth resistance without RCD tripping:
+ L-PE voltage range: 100V ÷ 690V
+ Frequency range: 42.5Hz ÷ 69Hz
+ Test current: <15mA
+ Measurement range: 1Ω ÷ 1999Ω
+ Resolution: 1Ω
+ Accuracy: 5.0%reading + 3Ω
- L-N, L-L, L-PE Loop / Line Impedance
+L-PE, L-N voltage range: 100V ÷ 690V
+Frequency range: 42.5Hz ÷ 69Hz
+Test current: 100mA
+Measurement range: 0.1Ω ÷ 199.9Ω
+Basic accuracy: ±(5.0%reading + 3digits)
Standard accessories
• C2065 Three wire cable Red, Black, Green with Shuko plug
• 4324-2 Pair of test tips Red/Black 2/4mm straight banana
• YABAT0001HT0 Alkaline battery 1.5V, type AAA, IEC LR03, 4 pcs
• YABRS0002HT0 Carrying bag
• YAMUM0066HT0 User manual on CD-ROM
• YAMUM0065HT0 Quick reference guide
• Calibration certificate ISO9000