1. PERFORMANCE TEST
DC Voltage: 5.0 ÷ 999.9; ± (1.0%rdg + 2dgt)
DC current (by mean external clamp) :
-1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)
1< FS ≤ 10: 0.001; 0.05
10< FS ≤ 100: 0.01; 0.5
100< FS ≤ 1000: 0.1; 5
DC Power (Vmeas > 150V):
1< FS ≤ 10: 0.000k ÷ 9.999k; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)
10< FS ≤ 100: 0.00k ÷ 99.99k; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)
100< FS ≤ 1000:0.0k ÷ 999.9k ; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)
Irradiance (by mean HT304N): 1 ÷ 40.0; ±(1.0%rdg + 0.1mV)
Temperature (by mean PT300N): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)
2. FUNCTIONALITY TE
DC Voltage @ OPC: 5.0 ÷ 999.9; ± (1.0%rdg + 2dgt)
DC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt)
DC Voltage @ STC: 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt)
DC Current @ STC: 0.10 ÷ 15.00; ± (4.0%rdg + 2dgt)
Irradiance (by mean HT304N): 1 ÷ 40.0; ±(1.0%rdg + 0.1mV)
Temperature (by mean PT300N): -20.0 ÷ 100.0; ±(1.0%rdg +1°C)
3. SAFETY TEST
Continuity Test (LOWΩ): 0.00÷ 199; ±(2.0%rdg + 2dgt)
Insulation Test (MΩ) – Mode TIMER: 250, 500, 1000; 0.01 ÷ 199; ±(5.0%rdg+ 5dgt)
Insulation Test (MΩ) – Mode FIELD (*), STRING (**): 250, 500, 1000; 0.1 ÷ 99; ±(20.0%rdg+ 5dgt)
Accessories provided
User manual and quick guide
ISO9000 calibration certificate
Standard Clamp HT4004
Bag BORSA2051
Set of Adapter KITPCMC4
Set of Adapter KITPCMC3
Set of Cabled and Alligator Clips KITGSC4
Multi- Language Software TOPVIEW2006