Input:
• Voltage: 110V or 220VAC, ±10%, single phase
• Frequency: 47-63Hz
• Fuse: 4A/250VAC
AC withstand test: Rated output: 5kV AC
Output frequency: 50/60Hz, for option
Output waveform: Sine wave, 1.3
Upper limit setting of leak current:
• Range: 0.01-12.00mA
• Resolution: 0.01mA
• Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak current:
• Range: 0.00-12.00mA
• Resolution: 0.01mA
• Accuracy: ±(2% of setting value+2digit)
DC withstand voltage test: Rated output: 6KV DC
Upper limit setting of leak current:
• Range: 0.01-12.00mA
• Resolution: 0.01mA
• Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak current:
• Range: 0.00-12.00mA
• Resolution: 0.01mA
• Accuracy: ±(2% of setting value+2digit)
Voltage setting:
• Range: 0-5000V AC; 0-6000V DC
• Resolution: 1V
• Accuracy: ±(2% of setting value+5V)
Voltage stability: ±(1% of setting value+5V)
Slow rising time:
• Range: 0.1-999.9S
• Resolution: 0.1S
• Accuracy: ±(0.1% of setting value+0.05S)
Test time:
• Range: 0.5-999.9S, 0 is continuous testing
• Resolution: 0.1S
• Accuracy: ±(0.1% of setting value+0.05 S)
Arc detection: Range: class 1 to class 9 can be set, 0 is non-detection arc status
Voltage display:
• Range: 0-5.00KV AC; 0-6.00KV DC
• Resolution: 0.01KV
• Accuracy: ±(3% of display value+3digit)
Current display:
• Range: 0.01-12.00mA AC; 0.01-6.00mA DC
• Resolution: 0.01mA
• Accuracy: ±(2% of display value+3digit)
Insulation resistance test: Rated output: 1000V DC
Voltage setting:
• Range: 500 - 1000V DC
• Resolution: 100V
• Accuracy: ±(2% of setting value+5V)
Voltage display:
• Range: 0.50KV – 1.00KV DC
• Resolution: 0.01KV
• Accuracy: ±2% of display value
Resistance display:
• Range: 1.000 - 2000MΩ
• Accuracy: ±(5% of display value+3digit) (1-1000MΩ); ±(10% of display value+3digit)(1000-2000MΩ)
Upper limit setting of resistance: 0-2000MΩ, 0 is non determination
Lower limit setting of resistance: 1.0-999.9MΩ
Delay time of determination:
• Range: 0.8 - 999.9 S, 0 is continuous determination
• Resolution: 0.1S
• Accuracy: ±(0.1% of display value+0.05 S)
Dimension: 326*102*380mm
Weight: 9kg