PERFORMANCE
Range: 0 – 1,000 cP
Measurement Time: 1 second
Accuracy: 1% of reading or +/- 0.1cP
Repeatability: 0.3% of reading or +/- 0.05cP
OUTPUTS / INPUTS
Analog: 2 × 4-20mA configurable, representing viscosity, ref. viscosity, or temperature
Digital: RS485 ModBus Data Link to host system or PC running ViscoLink
Power: 24v DC @ 80mA
TEMPERATURE
Integral Thermometer: Integrated temperature measurement
Standard Range: -50 °C to 150 °C
Extended Range: To order for greater than 150 °C *
PRESSURE
Standard Range: 50 Bar
Extended Range: To order for greater than 50 bar *
PIPE CONNECTION
Standard Fitting: 3/4” or 1” BSPP / NPS, 1.5” cone-seat (Swagelok™)
Special Fitting: Non-standard process connection to order *
ELECTRICAL CONNECTION
Cable Length: As required – not affected by cable length up to 1000m
Cable Type: Any standard instrument cable
CONSTRUCTION
All welded, crevice-free
MATERIALS
Head: SS316 ( EN 1.4401)
Sensor: SS316 ( EN 1.4401)
Sensor/Fitting Options: Alloy C22 (EN 2.4602)
Alloy C276 (EN 2.4819)
S32750 Duplex Steel (EN 1.4410)
Special Materials: Non-standard materials to order *
SURFACE FINISH
Standard: N6 0.8 Ra
Special Finish: Non-standard finish options and coatings to order *
WEIGHT: 3Kg
INGRESS PROTECTION
Standard: IP67
SOFTWARE
ViscoLink data viewing and logging PC software