Voltage Mode
Amplitude: ± 16 V
Resolution: 16 bits (488 µV steps) Monotonic to 2.0 mV
DC amplitude accuracy (90 days): ± (0.05% + 3.0 mV) (spec)
Compliance current: >20 mA @ 0 to ± 12 V de-rated linearly to 5 mA @ ± 16 mV
Short circuit current: <60 mA (spec)
Differential ripple and noise: <2 mV rms (20 Hz - 250 kHz, into 10 kΩ load)
Current Mode (typ except where noted)
Range: 0 to ± 20.00 mA
Resolution: 16-bit (610 nA steps) monotonic to 25 µA
Accuracy (90 days): ± (0.09% + 5.0 µA) (spec)
Compliance voltage: ± 12 V (spec)
Maximum open circuit voltage: <18 V
Differential ripple and noise: <2 µA rms (20 Hz - 250 kHz, into 250 Ω load)
Sample rate: 1 kSa/s per channel
Data Transfer: A16 or A24, D16
Size: C
Slots: 1
Connectors: P1/P2