Input power: AC 380V ±10% / 60Hz
Input active power: 6278 W
Resolution ratio: AD:16bit;DA:16bit
Input impedance: ≥100kΩ
Voltage
Constant voltage range: 0.3V~60V
Minimum discharge voltage: 3V
Accuracy: ± 0.1% of FS
Stability: ± 0.1% of FS
Output range/channel: 0.025A~5A
Accuracy: ± 0.1% of FS
Current
Constant voltage cut-off current: 0.01A
Stability: ± 0.1% of FS
Power
Output range/channel: 300W
Stability: ±0.2% of FS
Time
Current response time: maximum current rising time20ms
Working step time range: ≤(365*24)h/working step
Data record
Record data conditions:
Minimum time interval:100ms
Minimum voltage interval:120mV
Minimum current interval:10mA
Record frequency: 10Hz
Charge
Charge mode: constant-current charge,constant-voltage charge,constant voltage and current charge
Cut-off conditions: Voltage,current,relative time,capacity,-△V
Discharge
Discharge mode: constant current discharge, constant watt discharge
Cut-off conditions: Voltage,current,relative time,capacity,-△V
Impulse mode
Charge: Constant current,Constant power
Discharge: Constant current,Constant power
Minimum impulse width: 500ms
Number of pulses: one single pulse working step can support 32 different pulses
Continuous switch of charge and discharge: one pulse working step can continuously switch from charge to discharge
Cut-off conditions: Voltage,relative time
DCIR test: Support customized picking up point to perform DCIR calculation
Cycle
Loop test range: 1~65535 times
Single cycle working steps: 254
Loop nest: Nested loop function,max 3 layers
Working temp. range: 0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃)
Storage temp. range: -10℃~50℃
Working environment relative humidity range: ≤70% RH(no water vapor condensation)
Storage environment relative humidity range: ≤80% RH(no water vapor condensation)
Clamp specification and size
Clamp type: Polymer clamp
Cabinet size/unit(W*D*H)(mm): 30U(24”),730*600*1520