Power supply: AC220V or AC110V, 50/60Hz;
Cell type
1) Standard: 1.2V1, 2V, 6V and 12V
2) Customized: 12V ONLY or other uncommon battery types.
Discharge voltage range: 10V-264V with constant current in this ranges:(Constant current of 300A in the range of 198V-264V)
Discharge current range:
Single load bank: 0-300A
Parallel loads: 0-1500A (up to 5 loads)
Parallel load with other models of same rated voltage of 220V.
Accuracy:
Current: 1%
Voltage: 0.5% – 0.8%
Resolution
Current: 0.1 A or 0.5%
Voltage: 0.001 V
Sampling interval: 5s –1min
Discharge pattern: Constant current discharge
Display: 128*64 pixel, 5” TFT touch screen (resistive screen)
CDL power supply: 9~36Vdc
CDL measurement range: 0~15Vdc
Data transfer: USB, Wifi (for CDL to load bank and PC)
Cooling: Forced air cooling
Operation temperature: 0℃~40℃ (32 – 104 °F)
Humidity: 5%~90% Relative humidity
Standard: CE marking, EMC standard
Main unit dimension: 440*1025*650mm
Main unit weight: 75kg