For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Metrel MI 3122 Standard set Z Line-Loop / RCD Tester (10 mA~1000 mA)

ModelMI 3122 Standard set
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

RCD testing

Nominal residual current (A, AC): 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000 mA

Test current shape: Sine-wave (AC), pulsed (A)

RCD type: G (non-delayed), S (time-delayed)

Test current starting polarity: 0 ° or 180 °

Voltage range: 50 V ÷ 264 V (45 Hz ÷ 65 Hz)

Contact voltage (Measuring range/ Resolution/ Accuracy):

0.0 ÷ 19.9 V / 0.1 V / (-0 % / +15 %) of reading ± 10 digits

20.0 ÷ 99.9 V / 0.1 V / (-0 % / +15 %) of reading

Trip-out time (Measuring range/ Resolution/ Accuracy): 0 ÷ 300 ms / 1 ms / ±3 ms

Trip-out current (Measuring range/ Resolution/ Accuracy):

0.2xI∆N ÷ 1.1xI∆N (AC type) / 0.05xI∆N /±0.1xI∆N

0.2xI∆N ÷ 1.5xI∆N (A type, IDN ≥30 mA) / 0.05xI∆N / ±0.1xI∆N

0.2xI∆N ÷ 2.2xI∆N (A type, IDN <30 mA) / 0.05xI∆N / ±0.1xI∆N

Fault loop impedance (no disconnecting device or FUSE selected) (Measuring range/ Resolution/ Accuracy):

0.00 ÷ 9.99 Ω / 0.01 Ω / ±(5 % of reading + 5 digits)

10.0 ÷ 99.9 Ω / 0.1 Ω / ±(5 % of reading + 5 digits)

100 ÷ 999 Ω / 1 Ω / ± 10 % of reading

1.00 kΩ ÷ 9.99 kΩ / 10 Ω / ± 10 % of reading

Fault loop impedance (RCD selected - no trip out of RCD) (Measuring range/ Resolution/ Accuracy):

0.00 ÷ 9.99 Ω / 0.01 Ω / ±(5 % of reading + 10 digits)

10.0 ÷ 99.9 Ω / 0.1 Ω / ±(5 % of reading + 10 digits)

100 ÷ 999 Ω / 1 Ω / ± 10 % of reading

1.00 kΩ ÷ 9.99 kΩ / 10 Ω / ± 10 % of reading

Line impedance (Measuring range/ Resolution/ Accuracy):

0.00 ÷ 9.99 Ω / 0.01 Ω / ±(5 % of reading + 5 digits)

10.0 ÷ 99.9 Ω / 0.1 Ω / ±(5 % of reading + 5 digits)

100 ÷ 999 Ω / 1 Ω / ± 10 % of reading

1.00 kΩ ÷ 9.99 kΩ / 10 Ω / ± 10 % of reading

TRMS voltage monitor, Frequency (Measuring range/ Resolution/ Accuracy)

0 V ÷ 550 V / 1 V / ±(2 % of reading + 2 digits)

10.0 Hz ÷ 499.9 Hz / 0.1 Hz / ±(0.2 % of reading + 1 digit)

Phase rotation: 100 VAC ÷ 550 VAC / Result displayed 1.2.3 or 3.2.1

GENERAL DATA

Power supply: 6 x 1.5 V batteries or rechargeable batteries, size AA

Battery life: Typical 20 h

Overvoltage category: 600 V CAT III, 300 V CAT IV

Protection classification: Double insulation

Degree of protection: IP 40

Memory: 1900 measurements

Connectivity: RS232 and USB

Weight: 0.93 kg (without batteries)

Dimensions (W x H x D): 14 cm x 8 cm x 23 cm


MI 3122 Smartec Z-Loop-Line / RCD tester

20901090 Soft hand strap

A 1003 Mains plug

A 1296 Test leads 3 x 1.5 m (brown, green, blue)

83005447 12 V battery charging adapter

83005401 UK mains cable for charging adapter

A 1015 Test probe (blue)

A 1298 Test probe (brown)

A 1062 Test probe (green)

A 1310 Crocodile clip (blue)

A 1297 Crocodile clip (brown)

A 1309 Crocodile clip (green)

Short instruction manual

Instruction manual on CD

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts