For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Metrel MI 3155 Multifunctional Electrical Installation Tester (50 V ~ 2500 V)

ModelMI 3155
P/NMI 3155 EurotestXD
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Continuity

Test Current 7 mA 2-wire (Measuring range/ Resolution/Accuracy)

0.00 Ω ... 19.99 Ω / 0.1 Ω / ±(5 % of r. + 3 digits)

20.0 Ω ... 1999 Ω / 1 Ω / ±(5 % of r. + 3 digits)

Test Current 200 mA 2-wire (Measuring range/ Resolution/Accuracy)

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(3 % of r. + 3 digits)

20.0 Ω ... 199.9 Ω / 0.1 Ω / ±(5 % of r.)

200.0 Ω ... 1999 Ω / 1 Ω / ±(5 % of r.)

Test Current 200 mA 4-wire (Measuring range/ Resolution/Accuracy)

0.000 Ω ... 0.049 Ω / 0.001 Ω / ±(30 digits)

0.050 Ω ... 19.999 Ω / 0.001 Ω / ±(3 % of r. + 10 digits)

20.00 Ω ... 199.99 Ω / 0.01 Ω / ±(5 % of r.)

200.0 Ω ... 1999.9 Ω / 0.1 Ω / ±(5 % of r.)

Insulation Resistance (Measuring range/ Resolution/Accuracy)

Test Voltage 50/100/250 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 99.9 MΩ / 0.1 MΩ / ±(10 % of r.)

100.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(20 % of r.)

Test Voltage 500/1000 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(5 % of r.)

200 MΩ ... 999 MΩ / 1 MΩ / ±(10 % of r.)

Test Voltage 2500 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(5 % of r.)

200 MΩ ... 999 MΩ / 1 MΩ / ±(10 % of r.)

1.00 GΩ ... 19.99 GΩ / 0.01 GΩ / ±(10 % of r.)

RCD Test (Measuring range/ Resolution/Accuracy)

RCD Uc (Contact Voltage):

0.00 V ... 19.99 V / 0.1 V / (-0 %/+15 %) of r. ± 10 digits

20.0 V ... 99.9 V / 0.1 V / (-0 %/+15 %) of r.

RCD (t) (Trip Time):

0.00 ms ... 40.0 ms / 0.1 ms / ±1 ms

0.0 ms ... max. time / 0.1 ms / ±3 ms

RCD I Ramp (Trip Current):

0.2×IΔN ... 2.2×IΔN / 0.05×IΔN / ±0.1×IΔN

Impedance (Measuring range/ Resolution/Accuracy)

Zline (L-L, L-N) & Zloop (L-PE):

0.00 Ω ... 9.99 Ω / 0.01 Ω / ±(3 % of r. + 3 digits)

10.0 Ω ... 99.9 Ω / 0.1 Ω / ±(5 % of r.)

100 Ω ... 999 Ω / 1 Ω / ±(10 % of r.)

1.00 kΩ ... 9.99 kΩ / 10 Ω / ±(10 % of r.)

Voltage & Frequency (Measuring range/ Resolution/Accuracy)

Voltage TRMS (0, 14 ... 500 Hz):

0 V … 550 V / 1 V / ±(2 % of r. + 2 digits)

Frequency:

0.00 Hz ... 499.9 Hz / 0.01 Hz / ±(0.2 % of r. + 1 digit)

Earth Resistance (Measuring range/ Resolution/Accuracy)

3-wire Method:

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(5 % of r. + 5 digits)

20.0 Ω ... 199.9 Ω / 0.1 Ω / ±(5 % of r. + 5 digits)

200.0 Ω ... 9999 Ω / 1 Ω / ±(5 % of r. + 5 digits)

2-clamp Method:

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(10 % of r. + 10 digits)

20.0 Ω ... 39.9 Ω / 0.1 Ω / ±(20% - 30 % of r.)

General Data

Power Supply: 7.2 V (4400 mAh Li-Ion battery pack)

Overvoltage Category: 600 V CAT III; 300 V CAT IV

Protection Class: Double insulation

COM Port: BT, USB, RS232

Display: 4.3 inch Colour TFT touch screen (480 x 272 pixels)

Dimensions (L x H x W): 252 x 111 x 165 mm

Weight: 1.78 kg

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts