Continuity

Test Current 7 mA 2-wire (Measuring range/ Resolution/Accuracy)

0.00 Ω ... 19.99 Ω / 0.1 Ω / ±(5 % of r. + 3 digits)

20.0 Ω ... 1999 Ω / 1 Ω / ±(5 % of r. + 3 digits)

Test Current 200 mA 2-wire (Measuring range/ Resolution/Accuracy)

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(3 % of r. + 3 digits)

20.0 Ω ... 199.9 Ω / 0.1 Ω / ±(5 % of r.)

200.0 Ω ... 1999 Ω / 1 Ω / ±(5 % of r.)

Test Current 200 mA 4-wire (Measuring range/ Resolution/Accuracy)

0.000 Ω ... 0.049 Ω / 0.001 Ω / ±(30 digits)

0.050 Ω ... 19.999 Ω / 0.001 Ω / ±(3 % of r. + 10 digits)

20.00 Ω ... 199.99 Ω / 0.01 Ω / ±(5 % of r.)

200.0 Ω ... 1999.9 Ω / 0.1 Ω / ±(5 % of r.)

Insulation Resistance (Measuring range/ Resolution/Accuracy)

Test Voltage 50/100/250 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 99.9 MΩ / 0.1 MΩ / ±(10 % of r.)

100.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(20 % of r.)

Test Voltage 500/1000 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(5 % of r.)

200 MΩ ... 999 MΩ / 1 MΩ / ±(10 % of r.)

Test Voltage 2500 V:

0.00 MΩ ... 19.99 MΩ / 0.01 MΩ / ±(5 % of r. + 3 digits)

20.0 MΩ ... 199.9 MΩ / 0.1 MΩ / ±(5 % of r.)

200 MΩ ... 999 MΩ / 1 MΩ / ±(10 % of r.)

1.00 GΩ ... 19.99 GΩ / 0.01 GΩ / ±(10 % of r.)

RCD Test (Measuring range/ Resolution/Accuracy)

RCD Uc (Contact Voltage):

0.00 V ... 19.99 V / 0.1 V / (-0 %/+15 %) of r. ± 10 digits

20.0 V ... 99.9 V / 0.1 V / (-0 %/+15 %) of r.

RCD (t) (Trip Time):

0.00 ms ... 40.0 ms / 0.1 ms / ±1 ms

0.0 ms ... max. time / 0.1 ms / ±3 ms

RCD I Ramp (Trip Current):

0.2×IΔN ... 2.2×IΔN / 0.05×IΔN / ±0.1×IΔN

Impedance (Measuring range/ Resolution/Accuracy)

Zline (L-L, L-N) & Zloop (L-PE):

0.00 Ω ... 9.99 Ω / 0.01 Ω / ±(3 % of r. + 3 digits)

10.0 Ω ... 99.9 Ω / 0.1 Ω / ±(5 % of r.)

100 Ω ... 999 Ω / 1 Ω / ±(10 % of r.)

1.00 kΩ ... 9.99 kΩ / 10 Ω / ±(10 % of r.)

Voltage & Frequency (Measuring range/ Resolution/Accuracy)

Voltage TRMS (0, 14 ... 500 Hz):

0 V … 550 V / 1 V / ±(2 % of r. + 2 digits)

Frequency:

0.00 Hz ... 499.9 Hz / 0.01 Hz / ±(0.2 % of r. + 1 digit)

Earth Resistance (Measuring range/ Resolution/Accuracy)

3-wire Method:

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(5 % of r. + 5 digits)

20.0 Ω ... 199.9 Ω / 0.1 Ω / ±(5 % of r. + 5 digits)

200.0 Ω ... 9999 Ω / 1 Ω / ±(5 % of r. + 5 digits)

2-clamp Method:

0.00 Ω ... 19.99 Ω / 0.01 Ω / ±(10 % of r. + 10 digits)

20.0 Ω ... 39.9 Ω / 0.1 Ω / ±(20% - 30 % of r.)

General Data

Power Supply: 7.2 V (4400 mAh Li-Ion battery pack)

Overvoltage Category: 600 V CAT III; 300 V CAT IV

Protection Class: Double insulation

COM Port: BT, USB, RS232

Display: 4.3 inch Colour TFT touch screen (480 x 272 pixels)

Dimensions (L x H x W): 252 x 111 x 165 mm

Weight: 1.78 kg


Standard set

Instrument MI 3155 EurotestXD

4400 mAh battery pack

Power supply adapter 12 V / 3 A

Plug commander, 1.5 m

Test lead, 4-wire, 1.5 m

Test lead, 3-wire, 1.5 m

Test lead, 2-wire, 2.5 kV, 1.5 m

Test probe, 4 pcs (black, blue, green, red)

Crocodile clip, 6 pcs (black – 2 pcs, blue – 1 piece, green – 1 piece, red – 2 pcs)

Earth set 20 m

USB cable

Soft carrying bag

Soft carrying neck belt

Calibration certificate

Short instruction manual

Instruction manual*

Metrel ES Manager BASIC Licence*

SW 1201 Metrel ES Manager (program installation)*

*SW 1201 Metrel ES Manager and all documentation can be downloaded free of charge from Metrel Web server or Metrel Documentation center

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts