For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Michell Instruments Optidew 401 Chilled Mirror Hygrometer

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Performance

Dew Point Measurement Accuracy: ±0.15 °C (±0.27 °F)

Repeatability: ±0.05 °C (±0.09 °F)

Sensitivity: ±0.01 °C (±0.018 °F)

Response: Stable measurement at +10 °C (+50 °F) dew point within 1 minute.

Dew-Point Sensor

1. Single Stage

Dew Point Range: –25 to +90 °C (–13 to +194 °F)

Temperature Range: –40 to +90 °C (–40 to +194 °F)

Relative Humidity Range at 23 °C: 2.25–100% RH

Material: POM sensor head, aluminum body.

2. Dual Stage

Dew Point Range: –40 to +90 °C (–40 to +194 °F)

Temperature Range: –40 to +90 °C (–40 to +194 °F)

Relative Humidity Range at 23 °C: 0.45–100% RH

Material: POM sensor head, aluminum body.

3. Harsh Environment

Dew Point Range: –40 to +120 °C (–40 to +248 °F)

Temperature Range: –40 to +120 °C (–40 to +248 °F)

Relative Humidity Range at 23 °C: 0.45–100% RH

Material: PEEK sensor head, aluminum body.

Corrosion and Saturation Protection: Active component isolation system.

Mirror Temperature Measurement: Pt1000, Class A.

Recommended Sample Flow: Ambient conditions for environmental measurements to 2 Nl/min for flowing samples.

Maximum Pressure: 2,500 kPa.

Process Connection: M36 × 1.5.

Remote PRT

Temperature Measurement Accuracy: ±0.1 °C (±0.18 °F).

Temperature Measurement: Pt100, Class A.

Cables

Cable Lengths: 0.3 m, 3 m, 5 m, 10 m, and 20 m (11.81 inches, 9.84 ft, 16.4 ft, 32.81 ft, and 65.62 ft) available. Cables can be combined.

Minimum Operating Temperature:

Standard: –25 °C (–13 °F).

High-temperature version: –40 °C (–40 °F).

Maximum Operating Temperature:

Standard: +90 °C (+194 °F).

High-temperature version: +120 °C (+248 °F).

Remote Pressure Sensor (Optional)

Pressure Measurement Accuracy: ±0.25% FS.

Pressure Measurement Range: 0–160 kPa or 0–2,500 kPa.

Process Connection: 1/8-inch NPT-M.

Control Unit

Resolution: Selectable display resolution of 1 or 2 decimal places.

Measurement Units:

Dew point: °Cdp or °Fdp.

Relative humidity: %.

Absolute humidity: g/m³.

Volume concentration: ppmV.

Mixing ratio: g/kg.

Wet-bulb temperature (Twb): °C, °F.

Water vapor pressure (wvp): Pa.

Ambient temperature: °C, °F.

Pressure-converted dew point: °C, °F.

Pressure: kPa, bara, barg, psia, psig.

Enclosure: Bench-top.

Enclosure Material: ABS.

Analog Outputs: Two 0/4–20 mA outputs (maximum load: 500 Ω).

Digital Communications:

Modbus RTU over USB (standard).

Modbus RTU over RS485 (standard).

Modbus TCP over Ethernet (optional).

Alarms:

1 process relay.

1 alarm relay.

Both are Form C, rated at 1 A, 30 VDC.

Inputs: 4–20 mA input for the pressure sensor.

Data Logging: SD card slot (standard).

Ingress Protection: IP54.

Dimensions: 220 × 175 × 118 mm (8.66 × 6.89 × 4.65 inches).

Weight:

Control unit: 1.5 kg (3.3 lb).

Sensor: 200 g (7.05 oz).

Display: 5.7-inch color touchscreen.

Environmental Conditions: –20 to +50 °C (–4 to +122 °F), up to 100% RH non-condensing; optional IP65 connector version supports 100% RH condensing conditions.

Supply Voltage: 100–240 V AC, 50–60 Hz.

Power Consumption: 30 VA maximum.