Input: 334kW, 220V±10%, 3-Phase, 50Hz/60Hz
Output:
Voltage: 35V~500V, ±0.5V
Current: 1.5A-300A, ±0.1% FS
Resolution: AD 16bit, DA 16bit
Data Acquisition:
Frequency: 10Hz Max
Mode:
Min Time Interval: 100ms
Min Voltage Interval: 1V
Min Current Interval: 0.6A
Response Time 1msec, 10%-90% Current Range
Operation Mode:
Charge: Constant Current, Constant Voltage, Constant Resistance
Discharge: Constant Current, Constant Power, Constant Resistance
Simulation: Constant Current, Constant Power
End Conditions: Voltage, Current, Time, Capacity, Energy, -δV
Channel Control: Independent
Step Editor:
Cycles: Max 65535
Steps: Max 255
Loops: Max 3 nested loops
Step Time Format: 00:00:00.000 (mm:hh:ss.ms)
Input Impedance: ≥100kΩ
Noise: <75dB
Environment:
Operating: 15℃~40℃, ≤70% RH, No Condensation
Storage: -10℃~50℃, ≤80% RH, No Condensation
Battery Holders Options: Ring Terminal
Dimensions: 1600*1100*1980 (W*D*H mm)