AC Output Ratings
Phases/Output Channels: 1, 2 or 3
Power, Max (1Φ or 3Φ): 12kW/31.5kVA
Current Ranges (RMS per Φ): 6, 30A/Φ
Current Ranges (RMS 1Φ): 18, 90A
Peak Current: 3 x Max RMS
Voltage Ranges L-N: 10 - 175, 350VRMS L-N (Split Phase 250V Max)
Accuracy: 0.2% Set + 0.2% Rng
Resolution: 0.005% Rng
Distortion (THD): <1% @ 50/60Hz, Full power into
resistive load at 480VRMS (L-L)
DC Output Ratings
Power Max (1ch or 3ch): 12kW
Current Ranges (Per Ch.): 60, 30A/CH
Current Ranges (Per Sys.): 18, 90A
Voltage Ranges: 10 - 200, 400VDC
AC & DC Measurements
Voltage Range (LR, HR): 260, 520V Pk
Accuracy (AC RMS): 0.1% Rdg + 0.06% Rng
Accuracy (DC): 0.1% Rdg + 0.1% Rng
Current per Phase (LR, HR): 20, 100A
Accuracy (AC RMS): 0.1% Rdg + 0.1% Rng
Accuracy (DC): 0.2% Rdg + 0.1% Rng High Range, 0.2% Rdg + 0.3% Rng Low Range
Power: Voltage Rng x Current Rng
Additional Measurements: Energy (Ah, kWh, kVAh), AC Crest Factor, AC Power Factor, Waveform Capture
Waveform Digitizer
Data Acquisition: Output Voltage & Current
Sample Rate: 125k Samples/sec
Memory Depth: 64k Samples
Control
Local User Interface: Built-in Touch-Panel and PC-Based software tools including graphical user interface
External System Comm: LAN (Ethernet) supporting SCPI or VXI-11
Drivers: Ni-Compliant LabVIEW Drivers, Enerchron (opt.)
Input Power
Voltage: Universal Input – 380V to 480V ± 10% (L-L, 3 Phase, 50/60Hz)
Efficiency/Power Factor: > 85% / > 0.95
Current per Φ @ 380V: 25A
Current per Φ @ 480V: 24A