Technical specifications
Measurement values: Measurement ranges / resolution / accuracy
PCE-830 + PCE-6801
Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1): 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W
1.000 kW to 9.999 kW / 0.001 k W / ±1% ±8 W
10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W
100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW
1000 kW to 9999 kW / 1 kW / ±1% ±8 kW
PCE-830 + PCE-6801
Current AC (50 Hz or 60 Hz, auto range select, TRMS): 0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A
0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A
4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A
Voltage AC (50 Hz or 60 Hz, TRMS): 20.0 V to 500.0 V / 0.1 V / ±0.5% ±5 digits
(measure between phase and neutral)
20.0 V to 600.0 V / 0.1 V / ±0.5% ±5 digits
(measure between phase and neutral)
Harmonic distortion of AC voltage: 1º to 20º / 0.1% / ±1.0%
21º to 49º / 0.1% / 4% of reading ±2.0%
50º to 99º / 0.1% / 6% of reading ±2.0%
PCE-830 + PCE-6801
Harmonics of AC current in %: 1º to 20º / 0.1% / ±0.2% of reading ±1.0%
11º to 20º / 0.1% / ±2% of reading ±1.0%
21º to 50º (A)/ 0.1% / ±5% of reading ±1.0%
21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0%
51º to 99º / 0.1% / ±35% of reading ±1.0%
PCE-830 + PCE-6801
Power Factor (PF): 0.00 to 1.00 / 0.01 / ±0.04
PCE-830 + PCE-6801
Phase angle (Phi): -180° to 180° / 0.1° / ±1°
PCE-830 + PCE-6801
Total harmonic distortion: 0.0 to 20.0% / 0.1% / ±1%
20.0% to 100% / 0.1% / ±3% of reading ±5%
100% to 999.9% / 0.1% / ±10% of reading ±10%
Maximum measurement of AC voltage and current: 50 Hz / 19 µS / ±5% ±30 digits
60 Hz / 16 µS / ±5% ±30 digits
Peak value measurementof AC voltage and current: 1.00 to 99.99 / 0.01 / ±5% ±30 digits
Frequency range in automatic mode: 45 Hz to 65 Hz / 0.1 Hz / 0.1 Hz
Memory: 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors
Port: USB
Software and cable: Included, for Windows 2000, XP, ME
Display: Backlit LCD with dot matrix
Power: 8 AA batteries (Mignon)
Dimensions: 257 mm x 155 mm x 57 mm
10.1 in x 6.1 in x 2.2 in
Weight: 1.16 kg / 2.56 lbs
Operating conditions: Max. 85% relative humidity / -10 ... 50ºC / 14 ... 122°F
Type of protection / standards: IEC 61010, 600 V/CAT III
Dilivery Contents
1 x PCE-830 3-Phase-Power Meter
3 x Amp clamps - PCE-6801
4 x Alligator clips
4 x Safety test lines (3 m / 3.3 ft long),
8 x Batteries
1 x Mains adaptor
1 x Carrying case
1 x USB cable software
1 x User's manual