Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Specification
Type of measurement
AC voltage AC V
Measuring range: 10 ... 600V; Peak to peak
Resolution: 0.1V; 0.1V
Accuracy: ± (0.5% ... 3 digits); ± (5% ... 30 digits)
AC AC A
Measuring range: 5 ... 2000 A; Peak to peak
Resolution: < 100 A: 0.01 A / < 1000 A: 0.1 A; > 1000 A: 1 A
Accuracy: < 200 A: ± (1% + 0.5 A)/> 200 A: ± (1% + 5 A); ± (5% + 30 digits)
Power factor (PF)
Measuring range: 0 ... 1
Resolution: 0.001
Accuracy:± 0.0
Phase angle
Measuring range: -180° ... 180°
Resolution: 0.1°
Accuracy: ± 1° x PF
Frequency
Measuring range: 45 ... 65 Hz
Resolution: 0.1 Hz
Accuracy: ± 0.2 Hz
Active, blind & apparent power
Measuring range: 0 ... 9,999 m (W / VA / VAR)
Resolution:0.1 ... 0.001 M (W / VA / VAR)
Accuracy: ± (1.5% + 20 digits)
Harmonic AC V
Measuring range: 1 ... 20th order; 21 ... 50 okay
Resolution: 0.1V; 0.1V
Accuracy: ± (2% + 5 digits); ± (4% + 5 digits)
Harmonic AC A
Measuring range: 1 ... 20th order
Resolution:< 100 A: 0.01 A
Accuracy: ± (2% + 5 digits)
Alternating current
Measuring range: 21 ... 50 okay
Resolution:< 1000 A: 0.1 A; > 1000 A: 1 A
Accuracy:± (4% + 5 digits)
Harmonic AC V%
Measuring range: 1 ... 20th order; 21 ... 50 okay
Resolution: 0.1%; 0.1%
Accuracy: ± (2% + 10 digits); ± (4% + 20 digits)
Absolute harmonic distortion
Measuring range: 0 ... 20%; 20.1 ... 100%
Resolution: 0.1%; 0.1%
Accuracy: ± (2% + 5 digits); ± (6% + 10 digits)
Temperature type K thermocouple
Measuring range: -100 ... 199.9°C / -148 ... 391.8°F; 200
... 1300°C / 392 ... 2372°F
Resolution:0.1°C / 0.18°F; 1°C / 1.8°F
Accuracy: ± (1% + 1°C / 1.8°F); ± (1% + 2°C / 3.6°F)
Display: Graphic LCD
AC V input impedance:
10 MOhm
Frequency range: 40
Hz ... 1 kHz
Current Probe
Calibrated frequency: 45
... 65 Hz
Current Probe
Overload protection:
AC V:
720V RMS
AC A: 2100 A
Data storage: Micro
SD card
Refresh rate: 1
second
Display
Storage rate: 2
... 7200s
Data storage
Storage format: XLS
Interface:
Serial interface for live presentation to PC
(SOFT-LUT-USB is required)
Power supply:
2 x
1.5V AA battery
9V / 800-mA power supply
Current consumption: 60-mA
DC
Jaw Capacity: 50 mm
Operating conditions: 0
... 50°C / 32 ... 122°F, max. 80% rh
Weight: About 595 g /
1.3 lbs
Dimensions: 280 x 106 x 47 mm / 11 x 4.2 x 1.9 in
Delivery contents
1 x Power analyzer PCE-GPA 50
1 x Test lead set
2 x Crocodile clips
1 x Micro SD memory card
1 x Power supply 9V / 800-mA
2 x 1.5V AA battery
1 x Carrying bag
1 x User manual