Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

- Current measurement DC A:
Measuring range; Resolution; Accuracy (of measured value)
500 μA; 0.01 μA; ± (1% + 6 digits)
5000 μA; 0.1 μA; ± (1% + 6 digits)
50 A; 0.01A; ± (2.5% + 5 digits)
1000 A; 0.1 A; ± (2.5% + 30 digits)
- Current measurement AC A:
Measuring range; Resolution; Accuracy (of measured value)
500 μA; 0.01 μA; ± (1.5% + 30 digits)
5000 μA; 0.1 μA; ± (1.5% + 30 digits)
50 A; 0.01A; ± (2.5% + 30 digits)
1000 A; 0.1 A; ± (2.8% + 30 digits)
- Resistance measurement:
Measuring range; Resolution; Accuracy (of measured value)
500 Ω; 0.01; ± (1% + 9 digits)
5 kΩ; 0.0001; ± (1% + 5 digits)
50 kΩ; 0.001; ± (1% + 5 digits)
500 kΩ; 0.01; ± (1% + 5 digits)
5 MΩ; 0.0001; ± (3% + 10 digits)
50 MΩ; 0.001; ± (3.5% + 10 digits)
- Voltage measurement DC V:
Measuring range; Resolution; Accuracy (of measured value)
500 mV; 0.01 mV; ± (0.1 % + 8 Digit)
5 V; 0.0001 V; ± (0.1 % + 4 Digit)
50 V; 0.001 V; ± (0.1 % + 4 Digit)
500 V; 0.01 V; ± (0.1 % + 4 Digit)
600 V; 0.1 V; ± (0.5 % + 4 Digit)
- Voltage measurement AC V (50 Hz ... 100 Hz):
Measuring range; Resolution; Accuracy (of measured value)
500 mV; 0.01 mV; ± ( 0.8 % + 9 Digit) (at 50 Hz / 60 Hz)
5 V; 0.0001 V; ± (1 % + 30 Digit)
50 V; 0.001 V; ± (1 % + 30 Digit)
500 V; 0.01 V; ± (1 % + 30 Digit)
600 V; 0.1 V; ± (1 % + 30 Digit)
- Capacitance measurement:
Measuring range; Resolution; Accuracy (of measured value)
500 nF; 0.01; ± (3.5% + 40 digits)
5000 nF; 0.1; ± (3.5% + 10 digits)
50 μF; 0.001; ± (3.5% + 10 digits)
500 μF; 0.01; ± (3.5% + 10 digits)
5mF; 0.0001; ± (5% + 10 digits)
- Frequency measurement:
Measuring range; Resolution; Accuracy (of measured value)
50 Hz; 0.001; ± (0.3% + 2 digits)
500 Hz; 0.01; ± (0.3% + 2 digits)
5 kHz; 0.0001; ± (0.3% + 2 digits)
50 khz; 0.001; ± (0.3% + 2 digits)
500 kHz; 0.01; ± (0.3% + 2 digits)
5 Mhz; 0.0001; ± (0.3% + 2 digits)
10 MHz; 0.001; ± (0.3% + 2 digits)
- Duty cycle:
Measuring range: 5% ... 95%
Resolution: 0.1
Accuracy (of measured value): ± (1% + 2 digits)
Pulse width: 100 μs ... 100 ms
Frequency: 10 Hz ... 10 kHz
- Temperature:
Measuring range: -100 ... 1000°C / -148 ... 1832°F
Resolution: 0.1
Accuracy (of measured value): ± (1% + 2.5°C / 3.5°F)
-General technical data:
Conductor diameter: Max. 48 mm / 1.9 in
Display: Two lines 50,000 digits
Continuity test: 50 ohms / < 50 mA
Diode test: 0.3 mA / 2.8 V DC
Battery indicator: Battery icon when battery low
Overrange: OL, if measuring range exceeded
Sample rate: 2 Hz
Peak detection: > 1 ms
Thermocouple: Type K
Fuse: 500-mA ceramic quick-acting
AC bandwidth (AC A / AC V): 50 Hz ... 400 Hz
AC measurement: True RMS
Operating conditions: 5 ... 40°C / 41 ... 104°F, max. 80% RH at 31°C / 87.8°F
Storage conditions: -20 ... 60°C / -4 ... 140°F, max. 80% RH
Power supply: 9V block battery
Automatic shutdown: After about 30 minutes
Dimensions (W x H x D): 230 x 76 x 40 mm / 9 x 3 x 1.6 in
Weight: 315 g / < 1 lb
Safety: IEC 1010-1 (2001):
EN 61010-1 (2001)
CAT III 600V
CAT II 1000V
Degree of pollution 2
Delivery scope:
1 x Clamp meter PCE-HVAC 6
1 x Transport bag
2 x Test leads
1 x Battery 9V block battery
1 x ISO Calibration Certificate