Measuring range: Peak: 0.2~300A; DC: 0.4~300A
Output signal ratio: 10mV/A(100X)
Accuracy: 1.5%±5mV (typical)
Noise: 1mV rms
Fall/Rise time: 2.3μs
Reference conditions: 18℃~28℃,20~75%RH,Sine signal frequency 48Hz~65Hz, External magnetic field <40A/m,No dc component, no current carrier, center test sample, load impedance≥1MΩand≤100pF,DC~65Hz; Measurement former reset is 0,battery 9V±0.1V
Bandwidth(-3dB): DC-150kHz
Load impedance: ≥1MΩ and ≤100pF
Input impedance: 50Hz-0.39mΩ, 1000Hz-58mΩ
Working Voltage: 600V rms max
Adjacent conductor influence: 50Hz,<10mA/A
Jaw opening conductor position influence: 0.5% numerical reading
Battery/ battery life: 9V alkaline battery/ approx. 50 hours
Low battery Indicate: with green LED light when >6.5V
Overload indicator: When >6.5V,LED turns green and red
Automatic shutdown time: 10min
Dc zero adjustment: √
Jaw insert conductor size: One cable: dia. 30mm. Two cable :dia.24mm or 2х31.5х10mm bus bar
Temp. and Humidity: 0-50℃ and 20~75%RH
Output: The cable length 2M, BNC interface, and the special interface for multimeter can be customized
Size/weight/color: 224x97x44 (mm)/440g/Dark grey cabinet; Red jaws