- Sample ports: Max. 16, Min. 10
- Operating range:
+ Use in locations ISO 8 (Class 100,000) or cleaner
+ 0.1 to 0.3 µm particle counters: Use to simultaneously monitor ISO 3, 4, 5, and 6 (Classes 1, 10, 100, 1000)
+ 0.5 to 5.0 µm particle counters: Use to simultaneously monitor ISO 5, 6, 7, and 8 (Classes 100, 1000, 10,000, 100,000)
- Manifold Pump
+ Pumps required: 1 (single-phase)
+ Flow rate: > 100 ft3/min
+ Safety provision: Automatic pump shutoff
+ Power: 105 – 125 VAC, 60 Hz or 220-240 VAC, 50 Hz 10.9; Amp, single-phase
+ Dimensions (l, w, h); weight 10.6 x 11.2 x 16.2 in (27 x 28 x 41 cm);
- Manifold Module
+ Flow rate: 1.5 – 3 CFM per port (nominal)
+ Purge time (between ports): 15 sec recommended
+ Cross talk (from other ports): < 0.1%
+ Sample tubing: Bev-A-Line XX® 1/2” OD, 3/8” ID (part # MI-153)
+ Sample tubing length and bend: 25’ – 125’ per port. Minimum 9” radius for Bev-A-Line XX®
+ Fittings provided: 16 (or 32) self-locking, 1/2” OD, Legris® (L-Legris) fittings
+ Vacuum required: 30” – 55” water
+ Mounting orientation: Vertical; wall mounting bracket included
+ Power: Provided by control box via controller cable
+ Dimensions (l, w, h); weight: 13.5 x 13.5 x 15.3 in (34 x 34 x 39 cm); 13.5 lb (6.1 kg)
- Control Box
+ Controlling software: Facility Net/Pharmaceutical Net (purchased separately)
+ Communications protocol: Ethernet
+ Firmware setup modes: RS-232, Telnet
+ Ethernet outlets (2): Network/Primary sensor
+ Automatic alarm: Inadequate manifold vacuum
+ Mounting: Vertical or horizontal; built-in mounting holes
+ Power: 105 – 125 VAC, 60 Hz; 220 – 240 VAC, 50 Hz
+ Dimensions (l, w, h); weight: 7 x 8.5 x12.5 in (18 x 22 x 32 cm); 11.5 lb (5.2 kg); painted steel box
+ System operating conditions: Temperature: 59 – 95° (15 – 35 °C); Humidity: non-condensing
- System Components Included:
Manifold module, control box, pump,
operations manual, power cord, control
cable, wall-mounting bracket, monitor
exhaust tubing, pressure sensor tubing,
pump tubing, and clamps.
- Optional: Particle counter/sensor, ISPs, sample
tubing, communications cables (manifoldto counter/sensor), PC, Facility Net or Pharmaceutical Net.