Application
Slab thickness from a single side
Detection and localization of voids, pipes, cracks (parallel to surface), and honeycombing
Technical Data
Range: 0.1 – 7930 μs
Resolution: 0.1 μs (< 793 μs), 1 μs (> 793 μs)
Display: 7” colour display 800x480 pixels
Pulse Voltage UPV: 100 – 450 Vpp
Pulse Voltage UPE: 100 – 400 Vpp
Bandwidth: 20 – 500 kHz
Receiver Gain: 1x – 10’000x (0 – 80dB) [11 steps]
Memory: Internal 8 GB Flash memory
Regional Settings: Metric and imperial units and multi-language supported
Battery: Lithium Polymer, 3.6 V, 14.0 Ah
Battery Lifetime: > 8h (in standard operating mode)
Operating Temperature: 0°C – 30°C (Charging, running instrument); 0°C –
40°C (Charging, instrument is off); -10°C – 50°C (Non-charging)
Humidity: < 95 % RH, non condensing
IP Classification: IP54
Accessories: Consisting of: Pundit Touchscreen, Pundit Pulse Echo
Transducer incl. cable, contact tester, battery charger, USB cable, DVD
with software, documentation, carrying strap and carrying case
| Pundit PL-200 | Pundit PL-200PE |
| Through Transmission: Access from two sides |
Pulse Echo: Single side access |
![]() |
![]() |
| Assessment of Concrete Quality | |
| Ultrasonic Pulse Velocity | |
| Uniformity | |
| Compressive strength and SONREB | Slab thickness from a single side, eg. ground floors |
| Determination of crack depth | Detection and localization of voids, pipes, cracks (parallel to surface), and honeycombing |
| Modulus of elasticity | |
| Assessment of Epoxy and refractory materials | |
| Scan Modes | |
| A-Scans Line Scans |
A-Scans B-Scans |
| E-Modulus | Area Scan |
| Data Logging | |
| Area Scan | |