Power ranges: 5, 15, 50, 150, 500 W, full scale (150 maximum from 800 to 1000 MHz)
Frequency range: From 25 to 1000 MHz
Correction accuracy
From 25 to 100 MHz: ±7 of full scale, using correction chart
From 100 to 510 MHz: ±6 of full scale, no correction required
From 510 to 1000 MHz: ±7 of full scale, no correction required
Insertion loss
From 25 to 512 MHz: 0.10 dB max.
From 512 to 1000 MHz: 0.15 dB max.
VSWR
From 25 to 510 MHz: 1.08 max.
From 512 to 1000 MHz: 1.12 max.
Element Broadband (from 25 to 1000 MHz, 500 W max.), rotable for forward
and reflected power measurements, non-removable
Dimensions: 127 (W.) x 185 (H.) x 102 (D.) mm
Weight: 1.8 kg
Connectors: “Quick Match” standard N female Type (BNC, UHF, TNC male of female optional)