Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Measurement range
For LF, LS, LT and Lt:
- Upper limit: 137 (A weighting) // 137 (C weighting)
- Lower limit: 27.8 (A weighting) // 29.6 (C weighting)
For Lpeak Linear margin of measurement: 66-140 dB
Noise
- Electrical noise
Maximum: 20.2 (A weighting) // 22.2 (C weighting)
Typical: 14.5 (A weighting) // 16.7 (C weighting)
- Total noise (electrical + thermal microphone)
Maximum: 29.8 (A weighting) // 34.1 (C weighting)
Typical: 25.7 (A weighting) // 29.7 (C weighting)
Peak detector Lpeak
Onset time constant: < 75 µs
Microphone 1/2" condenser microphone with preamplifier incorporated.
- Equivalent impedance: 3000 Ω
- Nominal sensitivity: 16 mV/Pa in reference conditions
Frequency weighting: Complies with standard IEC 61672 class 2. A and C weightings
Time weighting: LF, LS, conforms to class 2 tolerances
Resolution: 0.1 dB
Influence of vibrations: For frequencies from 20 to 1000 Hz and 1 m/s2: <75 dB(A)
Power supply: Two 1.5 V AA (LR6) batteries
Typical duration: 24 h (with continuous use)
Dimensions: 82 mm (W.) x 291 mm (H.) x 20 mm (D.)
Weight: 463 g (with batteries) / 413 g (without batteries)