MOUNTING OPTIONS
Standard Wall Mount:
Controller Body Dimensions: 235 mm x 184 mm x 120 mm (9.3 in x 7.2 in x 4.7 in)
Weight: 1 kg (2.2 lb)
Enclosure Material / Description: Polycarbonate, flame resistant to UL91
Cable Entry Detail: 10 cable entry knock outs; 5x M20, 1 x M16 underside; 4 x 18 mm (0.7 in) dia(PG11) at rear
Enclosure Protection: IP65
Fascia Mount:
Controller Body Dimensions: 200 mm x 112 mm x 108 mm (7.9 in x 4.4 in x 4.3 in)
Weight: 1.3 kg (2.9 lb)
Enclosure Material / Description: Stainless steel back, Polycarbonate UL94-V0 front and bezel
Cable Entry Detail: N/A
Enclosure Protection: IP64
Rack Mount
Controller Body Dimensions: 10 HP X 160 mm D x 3U 128.5 mm H (6.3 in x 5.06 in)
Weight: 0.8 kg (1.7 lb)
Enclosure Material / Description: Aluminum Frame
Cable Entry Detail: N/A
Enclosure Protection: none
Panel Mount
Controller Body Dimensions: 72 mm W x 144 mm H x 176 mm D (2.8 in x 5.7 in x 6.9 in)
Weight: 1.4 kg (3 lb)
Enclosure Material / Description: ABS
Cable Entry Detail: N/A
Enclosure Protection: IP65 optional
PHYSICAL: ALL MOUNTING OPTIONS
Transducer Cable Extensions: 2-core screened
Maximum Separation: Up to 1,000 m (3,280 ft)
ENVIRONMENTAL
Max. And Min.Temperature (Electronics): -20 °C to +50 °C (-4 °F to +120 °F)
APPROVALS
CE Approval: Listed in the Certificate of Conformity within the manual
Flammable Atmosphere Approval: For installation in non-flammable area only. Most compatible transducers suitable for flammable atmospheres. See sensor / transducer datasheet or brochure.
PERFORMANCE
Accuracy / Repeatability: 0.25% of the measured range or 6 mm (0.2 in), whichever is greater
Resolution: 0.1% of the measured range or 2 mm (0.08 in), whichever is greater
Min. & Max. Range: 0 mm to 40 m (0 in to 131.2 ft). Dependent on sensor used. Ability to measure 50 m (164 ft) with dB50 when modified.
Rate Response: Fully adjustable
Echo Processing: DATEM (Digital Adaptive Tracking of Echo Movement)
OUTPUTS
Analog Output: Isolated (floating) output (to 150 V) of 4-20mA or 0-20mA into 500 Ω (user programmable and adjustable) 0.1% resolution
Digital Output: Full Duplex RS232
Volt Free Contacts, Number & Rating: 5 form “C” (SPDT) rated at 5 A at 240V AC
Display: 6 digits plus 12 character text, plus bar graph with direction indicators, remote communicator identifier
and program / run / test mode indicators
INPUTS
Analog Input (Optional): Isolated (floating) input (to 150 V) 4-20mA or 0-20mA source, open circuit voltage 33 V, 22 V at 4mA, 14 V at 20mA (user programmable and adjustable) 0.1% resolution
SUPPLY
Power Supply: 105 V AC +5% / -10% 50/60Hz, 230 V AC +5% / -10% 50/60Hz, 18-36 V DC, 10W maximum power (typically 6 W)
Fuses: 100mA at 170-240 V AC, 200mA at 85-120 V AC