Sensors: Electrochemical
Measuring Ranges: 0 – 1.5 ppm
Lower Detectable Limit (LDL): 0.1% Vol.
Response Time (T-90): 60 Seconds
Life Expectancy: 2-3 years normal service
Accuracy: +/- 5% of full scale (0.5% volume for oxygen)
Location: Indoor Class I, Div. 2
Temperature: 14°F to 104°F -10°C to 40°C
Humidity: 5-95% RH
Housing
Housing J
Sensor: Plastic or aluminum
Controls
Zero: Sets transmitter output to 4 mA with zero output from sensor
Span: Sets transmitter output to 20 mA with
Output: 4 – 20 mA signal
Operating Voltage: 19 VDC to 30 VDC
Controllers: Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems