Open Circuit Voltage Measurement (PV Terminals)
Display Range 0.0VDC - 1000VDC
Measuring Range 5.0VDC - 1000VDC
Resolution 0.1VDC maximum
Accuracy ± (0.5 % + 2 digits)
Enunciators DC voltage polarity correct or reversed
Short Circuit Current Measurement (PV Terminals)
Display Range 0.00ADC - 15.00ADC
Measuring Range 0.50ADC - 15.00ADC
Maximum Power 10kW
Resolution 0.01ADC maximum
Accuracy ± (1% + 2 digits)
Earth Continuity Resistance Measurement (4mm Terminals)
Test Voltage Open Circuit >4VDC, nominal
Test Current into 2 Ω >200mA
Display Range 0.00Ω - 199Ω
Measuring Range (EN 61557-4) 0.05Ω - 199Ω
Resolution 0.01Ω maximum
Accuracy ± (2% + 5 digits)
Test Leads Zero Zero up to 10Ω, by zero button
Visible Warning ≥30V AC or DC at inputs
Circuitry Protection Test inhibited if ≥30V AC or DC at inputs
Repeat tests as per IEC61557-4 Approx 4000 1 second test
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal)
Test Voltage Open Circuit 250V, 500V, 1000V (as per IEC61557-2)
Test Voltage Specification -0% +20% (open circuit)
Test Voltage @ 1mA >1mA into UN x (1000Ω/V)
Test Current Short Circuit <2mA
Display Range 0.05MΩ - 199MΩ
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal
Continued...
Measuring Range (EN 61557-2) 0.05MΩ - 199MΩ
Resolution 0.01MΩ maximum
Accuracy 0.05MΩ - 100MΩ ± (5% + 5 digits)
101MΩ - 199MΩ ± (10% + 5 digits)
Visible Warning ≥ 30V AC or DC at inputs
Circuitry Protection Test inhibited if ≥ 30V AC or DC at inputs
Repeat tests as per IEC61557-4 Approx 3000 1 second tests
Rpe Voltage Measurement (4mm Terminals)
Display Range 30V - 440VAC/DC
Voltage Measuring Range 30V - 440VDC
30V - 440VAC 50-60Hz
Resolution 1V
Accuracy ± (5% + 2 digits)
Operating Current (via AC/DC Current Clamp)
Display Range 0.1A - 40.0A
Current Measuring Range 0.1A - 40.0A DC
0.1A - 40.0A AC 50-60Hz
Resolution 0.1A
Accuracy ± (5% + 2 digits)
DC Operating Power (via AC/DC Current Clamp and PV Terminals)
Display Range 0.00kW - 40kW
Measuring Range 0.50kW - 40kW
Resolution 0.01kW
Accuracy ± (5% + 5 digits)
Instrument Dimensions and Weight
Weight 1.04kg / 2.3lb
Dimensions 26.4 x 10.7 x 5.8cm / 10.4 x 4.2 x 2.3”
Display Custom LCD with backlight
Power Source 6 x 1.5V AA cells
Battery life >1000 test sequences
Auto power down User programmable
Onboard memory Up to 200 complete test datasets
Connectivity
USB download to PC (CSV format)
Wireless “Solarlink TM” to Survey 200R (range ~30m/100ft