Measurement accuracy
accuracy class 0.5
total error (Non-linearity + hysteresis + temperature effect + repeatability):
-40..+20 °C ±3 % typically ±2 %
-20..+85 °C ±1 % typically ±0.7 %
85..100 °C ±2.5 % typically ±1.5 %
Response time: (10..90 %) < 1 ms
Pressure resistance: corresponds to metering range
Media temperature: -40..+125 °C
Ambient temperature: -40..+105 °C
Storage temperature: -40..+125 °C
Media: fluids and gases
Materials medium-contact: 1.4301
Supply voltage: 10..32 V DC
Analog output: 4..20 mA two-wire
Load: max. (battery voltage -10 V) / 20 mA
Electr. connection: for round plug connector M12x1, 4-pole
Reversal polarity protected: yes
Ingress protection: IP 65 / 67
Weight: approx. 0.2 kg
Conformity: CE
EMC
interference radiation
DIN EN 55011: < 30 dB µV/m
Interference immunity
DIN EN 61000-4-3: 25 V/m
Shock test
1 m onto steel plate (as per IEC68-2-32)
Vibration 20 g (as per IEC 68-2-6 and 68-2-36)