Energy storage capacitor: 20μF ±10%
Open circuit output voltage: 0.2-6kV ±5%
- Front time: 10μs ±30%
- Pulse half peak time: 700μs ±20%
Short circuit output current: Maximum 150A ±5% (impedance 40Ω)
- Front time: 5μs ±30%
- Pulse half peak time: 320μs ±20%
Output polarity: Positive, negative, positive and negative cycle, alternating positive and negative, first positive and then negative, first negative and then positive
Output impedance: 15Ω ±10%, 40Ω ±10%
Surge trigger method: Automatic or manual, single trigger
Number of surges: 1-99 times
Programmable test program: Built-in IEC standards and user-defined programs, up to 1000 groups
Surge interval time: 20-9999s
Built-in network capacity: DC50V, 0.1A
Built-in network coupling: Line-ground (T1+R1+T2+R2 at the same time to GND)
Built-in network coupling device: 100Ω+90V gas discharge tube per line
Use environment: Temperature: 15°C-35°C relative humidity 10%-75%
System power: AC220±10%, 50/60Hz, about 300W
Dimensions: Width 470mm×Height 260mm×Depth 500mm
Total Weight: About 30kg