Features
- Display: 6 digits LCD display with maximum 999999
- Noncontact IR and contact measurements.
- Range of noncontact measurement: 50~500mm.
- Sampling rate: >60rpm (0.5s); 12~60rpm (>1s); Averge (>2s)
- Functions: maximum/minimum values, data hold, average value, auto power off, buzzer, backlight
- Manual recording: 20,000 data
- Auto recording: 20,000 data
- Battery life: about 20 hours (with continuous measurement and buzzer off)
- Power: 9V (NEDA 1604 IEC 6F22 JIS 006P) x 1
External power supply
1.Support USB power input
2.Optional adaptor
RS-232 port instruction:
Output: Earphone port (Diameter 3.5mm/4 plug head).
Output voltage: 3.3V (LVTTL)
- Low battery voltage measurement
Electrical Specifications
Ambient temperature range: 18ºC (64ºF) ~ 28ºC (82ºF)
Noncontact:
- RPM (r/min): RPM/count measurement: 12~99960 ; Resolution 0.01/0.1/1 ; Accuracy ±0.04%±2dgt
- RPM (r/s): RPM/count measurement: 0.2~1666 ; Resolution 0.0001/0.001/0.01/ 0.1 ; Accuracy ±0.04%±2dgt
- Cycle (ms): RPM/count measurement: 0.6~5000 ; Resolution 0.0001/0.001/0.01/1 ; Accuracy ±0.04%±2dgt
- Counter: RPM/count measurement: 0~999999 ; Resolution 1 ; Accuracy ±1dgt ~ ±20dgt
Contact: Option 4100K
- RPM (r/min): RPM/count measurement: 12~19980 ; Resolution 0.01/0.1/1 ; Accuracy ±0.04%±2dgt
- RPM (r/s): RPM/count measurement: 0.2~333 ; Resolution 0.0001/0.001/0.01/ 0.1 ; Accuracy ±0.04%±2dgt
- ft/min: RPM/count measurement: 3.9370~6555 ; Resolution 0.001/0.01/ 0.1/1 ; Accuracy ±0.04%±2dgt
- yard/min: RPM/count measurement: 1.312~2185 ; Resolution 0.001/0.01/ 0.1/1 ; Accuracy ±0.04%±2dgt
- m/min: RPM/count measurement: 1.2~1998 ; Resolution 0.001/0.01/ 0.1/1 ; Accuracy ±0.04%±2dgt
- m/s: RPM/count measurement: 0.2~33.3 ; Resolution 0.001/0.001/0.01 ; Accuracy ±0.04%±2dgt
- Cycle: RPM/count measurement: 3~5000 ; Resolution 0.001/0.01/ 0.1/1 ; Accuracy ±0.04%±2dgt
- Counter: RPM/count measurement: 0~999999 ; Resolution 1 ; Accuracy ±1dgt ~ ±20dgt
Accessories
Meter
User’s Manual
9V alkaline Battery
Carrying case
USB cable and installation disk
Reflection tapeX2