Manufacturer: TES
Model: TES-3910
Original: Taiwan
- Inrush Current measurement
- Check 3Φ phase sequence
- Variable-frequency drive (VFD) V &Hz measurement.
- Lo-Z voltage measurement to drain ghost voltages.
- A measurement for HVAC flame sensors.
- mV measurement range to interface with other accessories.
- Crest Factor & Harmonic ratio measurement
- True RMS reading on AC and DC+AC mode
- Data Hold, Auto hold & Peak hold mode
- Max / Min record mode
- Data memory & read function (10 readings)
- AC Current (40Hz to 400Hz) VFD Trms :
+ Range /Resolution/ Sensitivity:
99.99A/ 10mA />0.25A
999.9A /100mA />2.5A
+ Accuracy: +/-2% +/- 20dgts (50, 60Hz); +/- 4% +/- 20dgts (40 to 400Hz)
+ Overload Protection: 1000A
- DC Current :
+ Range /Resolution/ Sensitivity:
99.99A/ 10mA />0.25A
999.9A /100mA />2.5A
+ Accuracy: +/-2% +/- 20dgts
+ Overload Protection: 1000A
- ACA Inrush Current : VFD Trms
+ Range/ Resolution/ Sensitivity
99.99A/ 0.01A/ >5A
999.9A/ 0.1A />50A
+ Measurement Time: 100mS
- DC mA(Burden Voltage : 3.6mV/ mA)
+Range /Resolution /Sensitivity
99.99mA /10nA/ 0.30 mA
999.9 m /A A100nA /3.0 mA
+Accuracy: +/-1% +/-20dgts
+Overload Protection 1000AAC
- AC m AVFD Trms (Burden Voltage : 3.6mV/ mA)
+Range /Resolution/ /Sensitivity
99.99 mA/ 10nA / 0.30 m A
999.9 m A/ 100nA / 3.0 mA
+Accuracy: +/- 1% +/-10dgts (50, 60Hz) / +/- 2% +/-10dgts (40~400Hz)
+Overload Protection: 1000AAC
- AC Voltage (40Hz to 400Hz) VFD Trms:
Range /Resolution/ / Sensitivity
999.9mV/ 0.1mV/[]/ 2.0mV
9.999V /1mV / 20mV
99.99V /10mV/ 200mV
600.0V/ 100mV/[+/- 2% +/- 20 dgts (40 to 400Hz)]/ 2V
Accuracy: +/- 1% +/- 10 dgts (50, 60Hz) / +/- 2% +/- 10 dgts (40 to 400Hz)/ 40~300Hz on mV range >2mV
- DC Voltage :
+ Range /Resolution/ / Sensitivity
999.9mV/ 0.1mV/ 2.0mV
9.999V/ 1mV/ 20mV
99.99V/ 10mV/ 200mV
600.0V/ 100mV/ 2V
+ Accuracy: +/-1% +/-20 dgts
- Resistance (Continuity<40Ω on the 999.9Ω range) :
+ Range/ Resolution
999.9Ω / 100m Ω
9.999KΩ/ 1Ω
99.99KΩ/ 10Ω
999.9KΩ/ 100 Ω
+ Accuracy:+/-1% +/-10 dgts
+ Overload Protection: 1000V
- 3Φ Phase sequence indication :
Range/ Frequency/ Response/ Overload Protection: 80V to 480V/ 50Hz - 60Hz /1000V
- Diode (Continuity<40mV) :
Range /Resolution/ Accuracy/ Overload Protection: 3.000V / 1mV / +/-2% +/-1dgt /1000V
- Frequency :
Range /Resolution/ Accuracy /Sensitivity
40Hz/1KHz / 0.1Hz/ +/- 0.5%rdg +/-2dgts/ ACV>1.2V, ACA>6A