Flue gas CO (with H₂-compensation)
Measuring range: 0 to 8000 ppm
Accuracy:
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
Resolution: 1 ppm
Reaction time t₉₀: < 40 s
Flue gas COlow
Measuring range: 0 to 500 ppm
Accuracy:
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
Resolution: 0.1 ppm
Reaction time t₉₀: < 40 s
Flue gas Draught
Measuring range: -9.99 to +40 hPa
Accuracy
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution: 0.01 hPa with fine draught option 0.001 hPa
Temperature
Measuring range: -40 to +1200 °C
Accuracy:
±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range)
Resolution:
0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)
Flue gas degree of effectivity, Eta (calculated)
Measuring range: 0 to 120 %
Resolution: 0.1 %
Flue gas loss (calculated)
Measuring range: 0 to 99.9 %
Resolution: 0.1 %
Flue gas CO₂ calculation (calculated from O₂)
Measuring range: Display range 0 to CO₂ max
Accuracy: ±0.2 Vol.%
Resolution: 0.1 Vol.%
Pressure measurement
Measuring range: 0 to +300 hPa
Accuracy:
±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)
Resolution: 0.1 hPa with fine draught option 0.01 hPa
Flue gas CO (without H₂-compensation)
Measuring range: 0 to 4000 ppm
Accuracy
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)
Resolution: 1 ppm
Ambient CO
Measuring range: 0 to 500 ppm
Accuracy:
±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm)
Resolution: 1 ppm
with CO probe 0632 3331
Ambient CO₂
Measuring range:
0 to 1 Vol.%
0 to 10000 ppm
Accuracy:
±75 ppm or ±3 % of mv (0 to 5000 ppm)
±150 ppm or ±5 % of mv (5001 to 10000 ppm)
with ambient CO₂ probe 0632 1240
Gas leak measurement for combustible gases (via gas leak detection probe)
Measuring range: 0 to 10000 ppm CH₄ / C₃H₈; Display range
Accuracy: Signal optical display (LED) audible signal via buzzer
Reaction time t₉₀: < 2 s
with gas leak detection probe 0632 3330
General technical data
Dimensions: 240 x 85 x 65 mm
Operating temperature: -5 to +45 °C
Display size: 240 x 320 pixels
Display function: Colour graphic display
Power supply: Battery: 3.7 V / 2,400 mAh; Mains unit: 6 V / 1.2 A
Maximum memory: 500 Measurement values
Storage temperature: -20 to +50 °C
Weight: 573 g
Set with flue gas analyzer testo 320 (with O2, CO measurement cell), compact 300 mm flue gas probe, Spare dirt filters, adpater, transport case and mains unit