Voltage: AC 220V ±10%, 50Hz
Resolution: AD: 16bit DA: 16bit
Input Resistance: ≥1 GΩ
Input Power: 25W
Voltage
Constant Voltage Range: 25mV-5V
Discharge Min Voltage: -5V
Accuracy: ± 0.05% of FS
Stability: ± 0.05% of FS
Current
Per Channel Current Range: Range 1: 5uA-1mA, Range 2: 1mA-5mA, Range 3: 5mA-10mA
Accuracy: ± 0.05% of FS
Constant voltage cutoff current: Range 1: 2uA, Range 2: 0.01mA, Range: 0.02mA
Stability: ± 0.05% of FS
Power
Per Channel Output Power: 0.05W
Stability: ± 0.1% of FS
Time
Current Response Time: <500us (10%FS-90%FS)
Step Time Range: ≤(365*24 )hour/step, Time Form Support 00 : 00 : 00 : 00 (h min s ms)
Data Recording
Record Condition
Minimum Time Interval: 100ms
Minimum Voltage Interval: 10mV
Minimum Current Interval
Range 1: 2uA, Range 2: 0.01mA, Range 3: 0.02mA
Record Frequency: 10Hz
Charge
Charge Mode: Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge, CPC
End Conditon: Voltage, current, relative time, capacity, -△V
Discharge
Discharge Mode: CCD, CPD, CRD, CVD, Constant Current and Constant Voltage Discharge
End Condition: Voltage, Current, Relative Time, Capacity, -△V
Pulse
Charge: CCC, CPC
Discharge: CCD, CPC
Min Pulse Width: 500ms
Pulse number: A single pulse step supports 32 different pulses
Automated Switch: Automated swith from charge to discharge for each pulse
End Condition: Voltage, Test Time
Cycle
Loop Measure Range: 1~65535 times
Max Steps Per Loop: 254
Nested Loop: Nested loop Function, Max Support 3 Layers
Protection
Software Protection
Power-down Data Protection
Off-line Testing Function
Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Hardware Protection: Additional Anti-reverse Protection Model
Channel Features: Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode: Independent Control
DCIR testing: Support
Voltage and Current Testing Sample: 4-wire connecting
Noise: <45dB
Database: MySQL Database
A Means of Communication of Upper Machine: TCP/IP Protocol
Data Output: EXCEL、TXT、Graph
Communication Interface: Ethernet Port
Per Unit Main Channels No.: 8