- Measurement Method
+ Flow velocity: Ultrasonic Pulse Doppler
+ Fluid level: Ultrasonic Pulse Transit Time
- Fluids : Sewage, Waste Water, Industrial Effluents, or Other Fluids with suspended matters or small bubbles which reflect ultrasonic waves with a free water surface (turbidity, approx. 60 ~ 50,000 mg/L)
- Fluid Temperature : 0 ~ +40°C
- Applicable Open Channel Open channels: Rectangular,Circular, etc. Closed Conduit
Dimensions of Circular type: Inner diameter ø250 ~ 5000mm
Dimensions of Rectangular: Width 250 ~ 5000mm
- Measurement Range : Flow velocity: -5 ~ +5 m/s . Water level: 0 ~ 5000 mm
- Measurement Accuracy : Within ±3% of Full Scale
- Main Unit Display : LCD: 16 × 16 Characters . Displayed Items: Flow rate/ Totalized Flow/ Flow Velocity/ Water Level, Measurement Units, and Functions (at configuration)
- Power Supply : AC90 ~ 132V, 180 ~ 264V, DC19 ~ 29V
- Power Consumption : Approx. 38VA (AC100V), approx. 58VA (AC240), Approx. 24W (DC24V)
- Output Signals
+ Flow Rate: 4 ~ 20 mA DC (allowable resistance: less than 750Ω)
+ Totalized Flow: Photo MOS Relay (Insulated)
+ Flow Velocity: 4 ~ 20 mA DC (allowable resistance: less than 750Ω)
+ Water Level: 4 ~ 20 mA DC (allowable resistance: less than 750Ω)
- Main Unit Weight : Approx. 16kg
- Main Unit Dimensions : W 332 × H520 × D170 (including mounting bracket)