Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Acceleration Input
Impedance: 100 kΩ or greater
Sensitivity: Current On: 5 or 10 mV/g
Sensitivity: Current Off: 1 or 10 mV/g
Max Input: ±1000 g
Accuracy
Acceleration (at 100 Hz REF): 10, 100, or 1000 range ±1%
Frequency Response (from REF): Acceleration 3 Hz to 20 kHz ±3%; output is 3 dB down at selected filter cutoff
Current: 3.5 ±1 mA
Connector: BNC
AC Output
Impedance: <100 Ω
Sensitivity: 5 Vrms or 5 V FS
Frequency Response: 3 Hz to 20 kHz
Connector: BNC
Interface – Power
Power: 6 V batteries; nominally 8-hr operation before charging
Controls
Meter Sensor mV/g Switch: 4-position switch selects “5” or “10” mV/g with current on or “1” or “10” mV/g with current off
Meter FS Power Switch: Selects “10,” “100,” “1000” FS range or “Power Off”
Filter Switch (3 dB cutoff 10%):
Position 1: 3 Hz HP, 2 kHz LP
Position 2: 3 Hz HP, 5000 Hz LP
Position 3: 3 Hz HP, 10,000 Hz LP
Position 20: 3 Hz HP, 20,000 Hz LP
Indicators
Vibration Meter: 3.5 digit DVM with LCD display
Sensor Open LED: Illuminates when the sensor is open
Sensor Short LED: Illuminates when the sensor is shorted
Batt LO LED: Illuminates when battery needs to be charged
OL LED: Illuminates if the input is overloaded or any FS is exceeded
Mechanical
Dimensions: 6" W × 7" H × 2.5" D (15.2 cm × 17.8 cm × 6.3 cm)