Frequency range:9 kHz-3.6 GHz
Frequency resolution: 1Hz
Sweep width range: 0Hz, 100Hz~3.6GHz
Sweep accuracy: ± Sweep width /(Scanning points -1)
Cursor frequency uncertainty: ± [Cursor frequency reading × reference frequency accuracy + 1% × sweep width + 10% × resolution bandwidth + cursor frequency resolution]
Cursor type: General, difference, difference pair, relative
Cursor function: Noise、 N dB bandwidth
RBW (-3 dB): 1 Hz~3 MHz, 1-3-10 stepping
Shape factor of resolution filter:<4.8:1(60dB:3dB), Gaussian like type
Video bandwidth (-3 dB): 1 Hz ~3 MHz, 1-3-10 stepping
Bandwidth uncertainty: < 5%
Amplitude measurement range (preamplifier off): DANL ~ +10 dBm, 100 kHz~1 MHz,
DANL ~ +20 dBm, 1 MHz~3.6 GHz
Reference level: -100 dBm ~ +30 dBm, Step 1 dB
Maximum input DC voltage: +/- 50 V DC
Maximum continuous wave RF power: 33 dBm, 3 minute, Input attenuation >20 dB
Display logarithmic level coordinates: 10 dB~100 dB
Display linear level coordinates: 0 ~Reference level
Level coordinate unit: dBm, dBmV, dBuV, V, W
Scanning points: 40001
Number of traces: 6
Detection mode: Positive peak, negative peak, sample, Normal, average (voltage / RMS / video), quasi peak
Trace function: Clear write, max hold, min hold, view, close, average
Frequency response: Preamplifier off: ±0.8 dB; ±0.4 dB, typ
Preamplifier on: ±0.9 dB; ±0.5 dB, typ
RBW switching error: ± 0.2 dB logarithmic resolution and ± 0.01 linear resolution relative to RBW at 10 kHz, nominal value
Input attenuation error: ±0.5 dB(20℃ ~30℃, fc=50 MHz, Preamplifier off, Attenuation relative to 20 dB, Input attenuation 1~51 dB )
Absolute amplitude accuracy: Preamplifier off: ±0.4 dB, Input signal level -20dBm (20℃ ~30℃, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, peak detector, attenuation input 20 dB)
Preamplifier on: ±0.5 dB, Input signal level -40dBm (20℃ ~30℃, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, peak detector, attenuation input 20 dB)
Full amplitude accuracy: ±0.7 dB(20℃ ~30℃, Fc>100 kHz, Input signal level -50 dBm~0 dBm, RBW=1 kHz, VBW=1 kHz, Peak detection, Input attenuation 20dB, Preamplifier off, 95% Confidence)
Voltage input standing wave ratio: Input attenuation 10 dB
1 MHz~3.6 GHz <1.5, Nominal value
Scanning time: 1 ms ~ 4000 s
Scanning mode: Sweep frequency, FFT
Scan rule: Continuous, single
Trigger source: Free, video, external
External trigger settings: level(5V TTL), Rising edge / falling edge
Tracking source:
- Frequency range: 100 kHz~3.6 GHz
- RBW: 30 Hz~1 MHz, Only scan mode is supported
- Output level range: -20 dBm~0 dBm
- Output level resolution: 1 dB
- Flatness output: +/-3 dB
- Maximum reverse input level: Average power: 30 dBm, DC : ±50 V DC
Interface: Trace source output,10MHz reference input, 10MHz reference output,Ext Trigger,HDMI,USB host, USB device,LAN, 3.5mm
Power: 100~240V AC, 50Hz/60Hz
Display: 10.1 inch TFT LCD (1280x800) touch
Product size (W×H×D): 368 mm×218 mm×120 mm
Product net weight: 4.5kg