Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Smart Digital Gas Transmitter with 4-20-mA + MODBUS output
Operating voltage: 18 to 30 VDC Feature:Swappable smart sensor Enclosure: Flameproof,LM-6
Cable entries: 1/2” NPT (2 entries)/ 3/4" NPT (2 entries) Relays: 3 potential free contacts
Certifications: ATEX/IECEX, SIL2,
Option Sensor
Datasheet
|
Model No. |
Description |
Ordering Code |
|
KwikSense Pro |
Smart Digital Gas Transmitter with 4-20-mA + MODBUS
output Operating voltage: 18
to 30 VDC Feature:Swappable smart
sensor Enclosure: Flameproof,LM-6 Cable entries: 1/2” NPT (2
entries)/ 3/4" NPT (2
entries) Relays: 3 potential free
contacts Certifications: ATEX/IECEX, |
KS1000A1 |
|
KwikSense Pro with SIL |
Smart Digital Gas Transmitter with 4-20-mA
+ MODBUS output Operating voltage: 18 to 30 VDC Feature:Swappable smart sensor Enclosure: Flameproof,LM-6 Cable entries: 1/2”
NPT (2 entries)/ 3/4" NPT (2 entries) Relays: 3 potential free contacts Certifications: ATEX/IECEX, SIL2, |
KS1000A2 |
|
KwikSense-SS |
Smart Digital Gas Transmitter with 4-20-mA + MODBUS
output Operating voltage: 18 to 30 VDC Feature: Swappable
smart sensor Enclosure: Flameproof,SS-316 Cable entries: 1/2” NPT (2
entries)/ 3/4" NPT (2
entries) Relays: 3 potential free
contacts Certifications: ATEX/IECEX, SIL2, INMETRO, MED |
KS00S0A2 |
|
KwikSense Lite |
Digital Gas
Transmitter with 4-20-mA industrial standard output Operating voltage: 18 to 30 VDC Feature: Fixed single gas sensor Enclosure: Flameproof,LM-6 Cable entries: 1/2”
NPT (2 entries)/ 3/4" NPT (2 entries) Relays: 1 potential free contact
(Optional) Certifications: ATEX/IECEX |
KL0100A1 |
|
KwikSense Lite-SS |
Digital Gas Transmitter with 4-20-mA industrial
standard output Operating voltage:
18 to 30 VDC Feature: Fixed
single gas sensor Enclosure: Flameproof,SS-316 Cable entries: 1/2” NPT (2
entries)/ 3/4" NPT (2
entries) Relays: 1 potential free
contact (Optional) Certifications: ATEX/IECEX |
KL01S0A1 |
|
KwikSense RD |
Smart Digital Remote Display with 4-20-mA + MODBUS
Operating voltage: 18 to 30 VDC Enclosure: Flameproof,LM-6 Cable entries: 1/2” NPT (2 entries) & 3/4" NPT
(1 entry) Relays: 3
potential free contacts Certifications: ATEX/IECEX, SIL2, INMETRO |
KR0004A1 |
|
KwikSense RD-SS |
Smart Digital
Remote Display with 4-20-mA + MODBUS Operating voltage: 18 to 30 VDC Enclosure: Flameproof,SS-316 Cable entries: 1/2” NPT (2
entries) & 3/4" NPT (1 entry) Relays: 3 potential free contacts Certifications: ATEX/IECEX, SIL2, INMETRO |
KR00S4A1 |
Option Sensor
|
Gas |
Ordering Code |
Range / Resolution |
Sensor Technology |
|
Acetic Acid |
SSA0074A |
0 - 30 ppm |
EC |
|
0.1 ppm |
|||
|
Acetylene |
SSA0099C |
0 - 100% LEL |
Pellister |
|
1% LEL |
|||
|
Ammonia |
SSA0082A |
0 - 100 ppm |
EC |
|
1 ppm |
|||
|
Ammonia |
SSA0082B |
0 - 1000 ppm |
EC |
|
1 ppm |
|||
|
Butadiene |
SSA0099V |
0-50 ppm |
PID |
|
1 ppm |
|||
|
Butadiene |
SSA0099S |
0 - 100% LEL |
NDIR |
|
1% LEL |
|||
|
Bromine* |
SSA0061A |
0 - 20 ppm |
EC |
|
0.1 ppm |
|||
|
Butanol |
SSA0099D |
0 - 100% LEL |
Pellister |
|
1% LEL |
|||
|
Carbon Dioxide |
SSA0025A |
0 - 5% v/v. |
NDIR |
|
0.01% v/v. |
|||
|
Carbon Dioxide |
SSA0025B |
0 - 100% v/v |
NDIR |
|
1% v/v |
|||
|
Carbon disulphide |
SSA0021A |
0 - 50 ppm |
PID |
|
0.1 ppm |
|||
|
Carbon disulphide |
SSA0021B |
0 - 100 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020D |
0 - 100 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020E |
0 - 200 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020F |
0 - 300 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020B |
0 - 500 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020A |
0 - 1000 ppm |
EC |
|
1 ppm |
|||
|
Carbon Monoxide |
SSA0020C |
0 - 2000 ppm |
EC |
|
1 ppm |
|||
|
Chlorine |
SSA0060B |
0-10 PPM |
EC |
|
0.1 PPM |
|||
|
Chlorine |
SSA0060A |
0 - 20 ppm |
EC |
|
0.1 ppm |
|||
|
Chlorine Dioxide |
SSA0062A |
0-1 PPM |
EC |
|
0.1 PPM |
|||
|
Ethylene |
SSA0097A |
0 - 1500 ppm |
EC |
|
5 ppm |
|||
|
ETO** |
SSA0083A |
0 - 20 ppm |
EC |
|
0.1 ppm |
|||
|
ETO** |
SSA0083B |
0 - 100 ppm |
EC |
|
1 ppm |
|||
|
Formaldehyde |
SSA0098A |
0 - 10 ppm |
EC |
|
0.1 ppm |
|||
|
HC (Methane) |
SSA0099A |
0 - 100% LEL |
Pellister |
|
1% LEL |
|||
|
HC (Methane) |
SSA0099G |
500 - 10000 ppm |
Solid State |
|
10 ppm |
|||
|
HC(MPS) |
Please Ask |
0 - 100% LEL |
MPS |
|
1% LEL |
|||
|
HC |
SSA0099H |
50 - 1000 ppm |
Solid State |
|
1 ppm |
|
Gas |
Ordering Code |
Range / Resolution |
Sensor Technology |
|
|
Hydrogen
(IIC) |
SSA0090C |
0 - 100% LEL |
Pellister |
|
|
1% LEL |
|
|||
|
Hydrogen (IIC) |
SSA0090A |
0 - 1000 ppm |
EC |
|
|
1 ppm |
|
|||
|
Hydrogen (IIC) |
SSA0090B |
0 - 100% LEL |
EC |
|
|
1% LEL |
|
|||
|
Hydro Carbon |
SSA0099H |
50 - 1000 ppm |
Solid State |
|
|
1 ppm |
|
|||
|
Hydrogen Chloride* |
SSA0070A |
0 - 20 ppm |
EC |
|
|
0.1 ppm |
|
|||
|
Hydrogen Cyanide |
SSA0075B |
0 - 30 ppm |
EC |
|
|
0.1 ppm |
|
|||
|
Hydrogen Cyanide |
SSA0075A |
0 - 100 ppm |
EC |
|
|
1 ppm |
|
|||
|
Hydrogen Fluoride* |
SSA0072A |
0 - 10 ppm |
EC |
|
|
0.1 ppm |
|
|||
|
Hydrogen Sulphide |
SSA0030B |
0-20 ppm |
EC |
|
|
1 ppm |
|
|||
|
Hydrogen Sulphide |
SSA0030A |
0 - 100 ppm |
EC |
|
|
1 ppm |
|
|||
|
Iso-Butane |
SSA0099O |
0 - 100% LEL |
Pellistor |
|
|
1% LEL |
|
|||
|
LPG |
SSA0099B |
0 - 100% LEL |
Pellister |
|
|
1% LEL |
|
|||
|
LPG |
SSA0099T |
0 - 100% LEL |
NDIR |
|
|
1% LEL |
|
|||
|
MEK |
SSA0099P |
0 - 100% LEL |
NDIR |
|
|
1% LEL |
|
|||
|
Methane |
SSA0099E |
0 - 100% LEL |
NDIR |
|
|
1% LEL |
|
|||
|
Methane |
SSA0099F |
0 - 100% v/v |
NDIR |
|
|
1% v/v |
|
|||
|
Methanol |
SSA0099K |
0 - 100 ppm |
EC |
|
|
1 ppm |
|
|||
|
Methanol |
SSA0099M |
0 - 500 ppm |
EC |
|
|
1 ppm |
|
|||
|
Methanol |
SSA0099U |
0 - 100% LEL |
Pellister |
|
|
1% LEL |
|
|||
|
Mercaptan* |
SSA0035A |
0 - 20 ppm |
EC |
|
|
0.1 ppm |
|
|||
|
Methyl Bromide |
SSA0051A |
0 - 200 ppm |
Solid State |
|
|
1 ppm |
|
|||
|
Mono Methyl
Amine |
SSA0087A |
0 -100 ppm |
EC |
|
|
1 ppm |
|
|||
|
N-Butane |
SSA0099N |
0 - 100% LEL |
Pellister |
|
|
1% LEL |
|
|||
|
Methanol** |
Please
Ask |
0 - 100 ppm |
EC |
|
|
1 ppm |
|
|||
|
Nitrogen Dioxide |
SS00081A |
0 - 20 ppm |
EC |
|
|
0.1 ppm |
|
|||
|
Oxygen |
SSA0010A |
0 - 25% v/v. |
EC |
|
|
0.1% v/v. |
|
|||
|
Ozone* |
SSA0015A |
0-1 ppm |
EC |
|
|
0.01 ppm |
|
|||
|
PCl3* |
SS00071A |
0-10 PPM |
EC |
|
|
1 PPM |
|
|||
|
Phosgene* |
SS00055A |
0 - 1 ppm |
EC |
|
|
0.01 ppm |
|
|||
|
|
||||
|
Gas |
Ordering Code |
Range / Resolution |
Sensor Technology |
|
Phosphine |
SSA0055A |
0 - 10 ppm |
EC |
|
0.01 ppm |
|||
|
Phosphine |
SSA0050B |
0 - 20 ppm |
EC |
|
0.1 ppm |
|||
|
Phosphine |
SSA0050C |
0 - 20 ppm |
EC |
|
0.01 ppm |
|||
|
Phosphine |
SS00050E |
0 - 2000 ppm |
EC |
|
1 ppm |
|||
|
Phosphine |
SSA0050D |
0 - 5000 ppm |
EC |
|
10 ppm |
|||
|
POCl3* |
SS00073A |
0-20 PPM |
EC |
|
1 PPM |
|||
|
Propane |
SSA0099J |
0 - 100% LEL |
Pellister |
|
1% LEL |
|||
|
Propane |
SSA0099I |
0 - 100% LEL |
NDIR |
|
1% LEL |
|||
|
Propylene |
SSA0099L |
0-2 % v/v |
NDIR |
|
0.01% v/v |
|||
|
Silane |
SSA0053A |
0 - 15 ppm |
EC |
|
1 ppm |
|||
|
Sulphur Dioxide |
SSA0040A |
0 - 20 ppm |
EC |
|
0.1 ppm |
|||
|
Vinyl Chloride (Vinyl
Chloro Monomer)* |
SSA0022A |
0 - 100 ppm |
EC |
|
1 ppm |
|||
|
VOC (Benzene) |
SSA0100C |
0-20 PPM |
PID |
|
0.1 PPM |
|||
|
VOC (Benzene) |
SSA0100F |
0 - 1000 ppm |
PID |
|
1 ppm |
|||
|
VOC (Isobutylene) |
SSA0100B |
0-40 PPM |
PID |
|
0.1 PPM |
|||
|
VOC (Isobutylene) |
SSA0100E |
0-100 PPM |
PID |
|
1 PPM |
|||
|
VOC (Isobutylene) |
SSA0100A |
0 - 1000 ppm |
PID |
|
1 ppm |
|||
|
VOC (Isobutylene) |
SSA0100D |
0-4000 PPM |
PID |
|
1 PPM |
|||
|
VOC (VCM) |
SSA0100G |
0-100 PPM |
PID |
|
1 PPM |
|
Accessories |
Ordering Code |
|
|
Splash Guard/Rain Shield |
ER003605 |
|
|
Gas Collection Cone |
ER004028 |
|
|
Duct Mounting Kit |
ER004091 |
|
|
Canopy (FRP) |
ER003869 |
|
|
Canopy (Metallic) |
ER001008 |
|
|
Pipe Mounting Kits |
ER004752 |
|
|
Flow Through
Adapter |
EF001557 |
|
|
1/2" NPT Cable
Gand(ATEX) |
ER003957 |
|
|
1/2" NPT Stopper(ATEX) |
EF003904 |