Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Voltage
Range: 100 mV; 1 V; 10 V; 100 V; 1000 V
Source Range: ±122.400 mV; ±1.22400 V; ±12.2400 V; ±122.00 V; ±1224.00 V
Accuracy (1year): 60+ 4 μV; 55+ 15 μV; 55+ 150 μV; 55+ 1.5 mV; 55+ 15 mV
Max. Output: 12 mA or more; 120 mA; 30 mA; 10 mA
Current
Range: 100 µA; 1 mA; 10 mA; 100 mA; 1 A; 10A; 30 A
Source Range: ±122.400 μA; ±1.22400 mA; ±12.2400 mA; ±122.400 mA; ±1.22400 A; ±12.2400 A; 0 to +36.720 A
Accuracy (1year): 150 + 20 nA; 70 + 30 nA; 70 + 300 nA; 90 + 3 μA; 350 + 70 μA; 380 + 1.2 mA; 540 + 1.8 mA
Max. Output: 30 V; 10 V; 2 V; 1.5 V
Temperature
Range: Pt100
Source Range: –200.0 to 850.0˚C
Accuracy (1year): ±0.12˚C
Max. Output: 0.1 to 2 mA
Resistance
Range: 400 Ω
Source Range: 1.00 to 400.00 Ω
Accuracy (1year): 75 + 0.015 Ω
Max. Output: 0.1 to 2 mA
Sweep
Target: Voltage/Current/Temperature/Resistance
Speed: Approx. 8/16/32/64 sec. selectable during 0 to 100%, 100 to 0% of setting
Output divider
Target: Voltage/Current/Temperature/ Resistance
Denominator: m 4 to 15
Numerator:n 0 to 15 (n ≤ m)
Deviation Target
Target: Voltage/Current/Temperature/Resistance
Variable range: ±20.00%
Operation: Two dials
Resolution of the first dial: 0.2% of (MAX − MIN)
Resolution of the second dial: 0.01% of (MAX − MIN)
Deviation: preset OFF/0/2%/5%
Transient response time
Voltage/Current generation: Approx. 500 ms (except for 1000 V range), approx. 3 s (1000 V range) (No load, Time to reach 0.02% of final value)
RTD/Resistance generation: Within 0.1 ms (Time constant at changing current)
Warm-up time: Approx. 30 minutes
Operating environment: Temperature: 5°C to 40°C; Humidity: 20% RH to 80% RH
Storage environment: Temperature: –15°C to 60°C; Humidity: 20% RH to 80% RH
Operating Height : 2000 m or less
Operating Attitude: Horizon
Rated supply voltage: 100 VAC to 120 VAC, 200 VAC to 240 VAC
Permitted supply voltage range: 90 VAC to 132 VAC, 180 VAC to 264 VAC
Rated supply frequency: 50 Hz/60 Hz
Permitted power supply frequency range: 48 Hz to 63 Hz
Maximum power consumption: 200 VA
Withstand voltage: 1500 VAC for 1 minute between the power supply and case.
Dimensions: 426 (W) × 177 (H) × 400 (D) mm
Weight: Approx. 13 kg