Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

AC current: 20mA/200mA, 200A(0~100A), 200A(100.1~200A); 2.0+4 (50/60Hz) WIDE(40~400Hz) at 20mA/200mA, 200A(0~100A)
Method of detection: Mean value
Display: LCD(Digital display:1999 counts)
Response time: Approx. 2 seconds
Range switching: Manual-range
Data hold: On all range
Operating temperat ure and humidity : 0-40C 85% RH or less (no condensation)
Effect of external magnetic field: 10mA or less in proximity to a 14.4mm-dia conductor carrying 100A
Effect of conductor position: Within 5dgt for 0 to 50A, or 2% for 50 to 200A (10mm-dia conductor at inside the jaw)
Effect of residual current: 10mA or less in proximity to a 10mm-dia conductor carrying 50A
Safety standard: Conforms EN61010-1, EN61010-2-032
Circuit voltage: 300Vrms or less
Withstanding voltage: 4240V AC for 5 sec
Power supply: LR-44x2(3V) or SR-44x2
Batttery life: Approx. 15 hours (continuous)
Consumed current: Approx. 5mA
Auto power-off: Approx. 10 minutes
Diameter of measurable conductor: 24mm at maximum
Dimensions: Approx. 60(W)149(H)26(D)mm
Weight: Approx. 120g
Accessories: User's manual, batteries, carrying case(93033)