Gastec 112 Quick-measuring Detector tubes Ethanol C2H5OH (0.01~ 7.5%)
Manufacturer: Gastec Model: 112 - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
Indicator: 0.1 to 2.5%
Measuring Range:
+ 0.01 to 0.05%, Number of Pump Strokes 2
+ 0.05 to 2.5%, Number of Pump Strokes 1
+ 0.05 to 2.5%, Number of Pump Strokes 1/2
Sampling Time: 1 mimute per pump stroke
Colour Change: Pink → Pale blue
Reaction Principle: C2H5OH + Cr6+ + H2SO4 → Cr3+
Coefficient of Variation: 15% (for 0.05 to 0.5 %), 10% (for 0.5 to 2.5 %)
Nr. of tests: 10
Pump: GV-100S/110S
Measuring Range |
|
|||
Number of Pump Strokes |
|
|||
Correction Factor |
|
|||
Sampling Time | 1 minute per pump stroke | |||
Detecting Limit | 0.004% (n=2) | |||
Colour Change | Pink → Pale blue | |||
Reaction Principle | C2H5OH + Cr6+ + H2SO4 → Cr3+ | |||
Coefficient of Variation | 15% (for 0.05 to 0.5 %), 10% (for 0.5 to 2.5 %) | |||
Shelf Life | 3 Years | |||
Corrections for temperature & humidity | Temperature correction is necessary | |||
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Carbon monoxide | No | No | |
Carbon dioxide | No | No | |
Alcohols | + | Pale blue |
Calibration gas generation | Static gas dilution method |
TLV-TWA | TLV-STEL | Explosive range |
- | 1000ppm(2014) | 3.3 to 19% |
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment